Page 94
22.10.2019
R01.43
Strategy 1:
Components are not supported at all, but up to three different configurations
can be called up. The intensity can be controlled in seven steps from 0-100%.
Strategy 2:
Components can be separated and conveyed with two configurations. The in-
tensity can only be set here from 0% to 100%.
Strategy 3: (available from ControlUnit Firmware v1.40)
Components can be separated and conveyed with two configurations. The in-
tensity can be adjusted from 0% to 100% in several steps.
HINWEIS
From ControlUnit Firmware v1.40 the „Direction“ Control is im-
proved for digital In/Outputs. From this Version strategy 3 is pos-
sible.
Calculation of the direction value when using digital In-/Outputs from ControlU-
nit Firmware v1.40.
𝐷𝑖𝑟𝑒𝑐𝑡𝑖𝑜𝑛 𝑉𝑎𝑙𝑢𝑒 =
𝑀𝑎𝑥 𝑉𝑎𝑙𝑢𝑒 + 1
360
∗ 𝑡𝑎𝑟𝑔𝑒𝑡 𝑑𝑖𝑟𝑒𝑐𝑡𝑖𝑜𝑛[°]
INSTRUCTION
In 90% of the applications it is sufficient to separate the compo-
nents by vibrations. Conveying components is often not neces-
sary. Here strategy 1 should be followed.
INSTRUCTION
In alternative control interfaces such as TCP / IP or Profibus,
these limits do not exist, and e.g. up to 50 configurations can be
used.