26
CS6-BA-vers.1.7 gb. 20190312
4.1.2 Fault during operation
Fault
Possible cause
Fault clearance
The CS-compact swivel
comes firmly into the
end positions
The stop / shock are not
set correctly.
Adjust the stop / shock
Fixed strike again in the
end positions
Damping elements are
defective
Replace damping elements
The CS module remains
in a terminal position
No signal on the proximity
switch / sensor
Adjust proximity switch /
sensor
The CS module will
again be in the end
positions
Sensor is faulty
Replace sensor