Installation, assembly and setting
Assembly instructions
DE
EPS Handling systems
Date 08.09.2021
Version 2.0
83–112
5.4.2 Axis controller C12xx
Technical data
C1250-EC-XC
C1250-IP-XC
C1250-PL-XC
C1250-PN-XC
Logistics supply
24 VDC
24 VDC
24 VDC
24 VDC
Motor power supply
24 - 72 VDC
24 - 72 VDC
24 - 72 VDC
24 - 72 VDC
Max. motor output
current (at 72 V)
25 A
25 A
25 A
25 A
Bus systems
Interfaces
EtherCat
CANopen
DeviceNet
RS485/232
Digital I/Os
Master encoder
Ethernet IP
CANopen
DeviceNet
RS485/232
Digital I/Os
Master encoder
PowerLink
CANopen
DeviceNet
RS485/232
Digital I/Os
Master encoder
Profinet
CANopen
DeviceNet
RS485/232
Digital I/Os
Master encoder
Max. power
consumption
30 W
30 W
30 W
30 W
Protect. class
IP 20
IP 20
IP 20
IP 20
Operating temperature 0 - 40 °C
0 - 40 °C
0 - 40 °C
0 - 40 °C
Ground
0.7 kg
0.7 kg
0.7 kg
0.7 kg
Distance between
controllers
20 mm left/right
50 mm bottom/top
20 mm left/right
50 mm bottom/top
20 mm left/right
50 mm bottom/top
20 mm left/right
50 mm bottom/top
Fuse protection 72 V
supply
16 AT
16 AT
16 AT
16 AT
Fuse protection 24 V
supply
3 AT
3 AT
3 AT
3 AT
Technical data
C1250-SC-XC
C1250-SE-XC
Logistics supply
24 VDC
24 VDC
Motor power supply
24 - 72 VDC
24 - 72 VDC
Max. motor output current (at 72
V)
25 A
25 A
Bus systems Interfaces
Sercos III
CANopen
DeviceNet
RS485/232
Digital I/Os
Master encoder
Sercos over EtherCAT CANopen
DeviceNet
RS485/232
Digital I/Os
Master encoder
Max. power consumption
30 W
30 W
Protect. class
IP 20
IP 20
Operating temperature
0 - 40 °C
0 - 40 °C
Ground
0.7 kg
0.7 kg
Distance between controllers
20 mm left/right
50 mm bottom/top
20 mm left/right
50 mm bottom/top
Fuse protection 72 V
Supply
16 AT
16 AT
Fuse protection 24 V supply
3 AT
3 AT
DANGER
Danger when the safety door is open!
There is a high risk of injury when the safety door is open!
For the C11xx controller, the safety relay input (X33) must be deactivated