Commissioning
90 – 112
Assembly instructions EN
EPS Handling systems
Date 08.09.2021
Version 2.0
6 Commissioning
In addition, observe the instructions in the operating manuals of the
respective individual modules!
6.1 Safety instructions for commissioning
Also observe the safety instructions in
chap. 2 „Safety instructions“ in this
manual.
DANGER
Danger! Risk of electric shock!
If work on electrical components is required, ensure that the work is carried
out properly, failure to do so will cause serious or fatal injuries.
Work on the machine's electrical equipment may only be performed by
skilled electrician or trained personnel under the supervision of a skilled
electrician in accordance with all relevant electrical regulations.
CAUTION
Danger of injury in the working area of the EPS!
Due to the decentralised control system, the operator of the EPS must not
necessarily stand next to the module during operation so that he may not
have a complete view of the working area. Persons in the working area may
be injured.
During operation, ensure a good overview of the working area.
Unauthorised persons are not allowed in the work area.
CAUTION
Risk of injuries due to uncontrolled parts movements!
When the control is switched on, signals from the control can lead to
unintentional movements of the EPS system and cause serious injuries or
damage to property.
Before working on the EPS system, make sure that the control unit is
switched off and secured against being switched on again.
Only connect or disconnect the cables when the control unit is switched off.
CAUTION
Risk of injury due to mounted components!
Attachments on the EPS system can be a risk in conjunction with moving
parts.
Take appropriate measures to ensure safe operation!