Design and description
Assembly instructions EN
GE-25-P
Date 02.11.2021
Version 1.0
25–48
Functional description of the "READY" and "ERROR" LEDs
Display
Colour
Function
READY
GREEN Indicates whether voltage is connected.
Lights up
as long as voltage is applied to the GE-25-P.
Does
not light up
if no voltage is applied to the product.
ERROR
RED
Indicates whether there is a warning or an error.
Does
not light up
if no warning or error is present and the GE-25-
P is ready for operation.
Lights up
when there is an "Overtemperature" warning.
The phase current of the motor is limited to “IDauer”.
Closing and opening time may increase.
Automatically deleted when warning is no longer present
Flashes slowly
(approx. every 1.2 s) when an "overtemperature"
error is present
The GE-25-P goes into sleep mode until it has cooled down.
The commands
“Open gripper
” and
“Close gripper”
are not
processed.
The error must be acknowledged (
Acknowledge error)
Flashes
quickly
(approx. every 0.6 s) when the rotary switch
"Gripping force" is between two switching positions.
Error acknowledgement (Digital I/O):
To acknowledge the error, proceed as follows:
1. Wait until the GE-25-P has cooled down.
2. Control both digital inputs (PIN 2 and PIN 4) with “High” signal.
or
:
Disconnect and reconnect the power supply.
- LED “Error” goes out.
The error is acknowledged.