R05.0
16/05/2019
Page 25
6.3
Control device
The HLF is connected to the 230V/50Hz AC system via an IRG or MSG controller and
can be rated for other mains voltages and frequencies, e.g. 115V/60Hz. They operate in
full-wave mode at double mains frequency, i.e. at 50Hz AC, with a vibration frequency of
100Hz, in half-wave mode at single mains frequency with a vibration frequency of 50Hz.
Vibration displacement and thus the transport speeds are infinitely adjustable due to
magnet current and thus magnetic force variability.
Soft-starting, all IRG and MSG types can be mounted in various different ways and offer
extra controls for photoelectric barriers, initiator elements, or extern 24VDC signal. For a
detailed description of the controllers refer full-range catalogue from AFAG GmbH.
Third-party controllers can also be used as long as they meet the technical requirements.
Table 10:
Controllers for HLF- Linear feeder
Type
Power supply
Order number Comments
IRG1-S
230 V / 50 Hz
50360105
Control with no timer function
External target value preset
115 V / 60 Hz
50360106