Page 10
16/05/2019
R05.0
Table 1:
Technical data
Description
Units HLF07-M HLF12-M HLF25-M HLF50-M
Dimension
A
[mm]
400
500
800
800
B
[mm]
25
30
38
44
C
[mm]
10
10
10
10
D1
[mm]
7
9
9
11
D2
[mm]
4 x M5
4 x M5
4 x M6
4 x M6
D3
[mm]
2 x 4
H7
2 x 4
H7
2 x 5
H7
2 x 5
H7
E
[mm]
36
42
50
60
F
[mm]
73
80
108
140
G
[mm]
80
100
120
190
H
[mm]
50
59
86,5
96,8
K
[mm]
60
80
100
170
M
[mm]
170
200
260
350
N
[mm]
2 x 4
H7
2 x 4
H7
2 x 5
H7
2 x 5
H7
P
[mm]
150
180
240
320
Ideal track weight
[kg]
0,7
± 0,05
1,2
± 0,05
2,5
± 0,1
5,0
± 0,1
Max. track weight
[kg]
0,9
1,5
3,0
5,5
Weight of basic device
[kg]
1,8
3,0
6,3
12,5
Mech. osc. frequency
[Hz]
Double supply frequency
Power supply
[V/Hz]
230/50 or 115/60
Max. power consumption
[VA]
15
19
100
170
Degree of protection
-
IP 54
Temperature range for operation
[C°]
+10 to +45
Noise emission: Continuous noise
pressure level (without transported
material)
[dB]
<70
Measuring height/measuring dis-
tance
[m]
1,6/1
Measurement direction with respect
to the noise source
[°]
90
Measurement method
-
A-evaluation
Various sizes are available (see Table 1: Technical data) depending on the area of appli-
cation and available space. The main criterion is the working weight (track length) and
the space available for installation.
Two Afag Linear Feeder versions are available: 230V/50Hz and 115V/60Hz.
Various Afag control devices (see chapter 6.3 Control device) are available for controlling
the Linear Feeder.