Page 12
16/05/2019
R06.0
4 Operating instructions
4.1 Standard operation
No further settings are required for standard operation mode once the controller is
switched on. The only thing required for an uninterrupted operation is the re-filling of
the dosing channel.
4.2 Adjustments and settings of the NVD
Basically the NVD and channel are adjusted in the standard configuration. This means
that all oscillating elements are set optimally.
The following factors however influence the combination NVD / channel:
-
the parts to be conveyed (size, weight, shape, material and condition)
-
the conveying capacity
-
the quantity filled
-
the foundation
-
Surrounding (are there other oscillating components with a disturbing influence)
Procedure for adjustment of the oscillating system:
WARNING
Unplug the power cable, before proceeding with further actions!
1.
check control unit settings
(see separate control unit’s operating instructions)
2. Remove the casing and check that all springs and fixing screws are tight.
3. Check that the type and frequency of the magnets is correct
(see chapter 2.3)
4. check the magnet distance and set if necessary
(see Chapter 5.5)
5. Switch on the NVD and alter the transport speed with the controller regulator
6.
Depending on the transport material, additional springs have to be installed or
removed.
(see chapter 5.3)