Page 16
16/05/2019
R06.0
Bowl feeder does not run after switch on
Cause of fault:
Fault repair
Plug not connected
Connect plug
Connecting cable between NVD and
controller not plugged in
Connect plug
Regulator on controller set to „0“
Turn regulator to position
Defective fuse in control unit
Replace fuse
Bowl feeder lacks performance after operating for a certain length of time
Cause of fault:
Fault repair
The spring package fixing screws have
become loose
Remove the casing and retighten all
spring package screws
The screw securing the bowl to the
vibration plate has become loose
Retighten the screw
The air gap between the magnetic coil
and the anchor bolt is no longer correct
Remove the casing and readjust the air
gap
(see chapter 5.5)
Spring broken
Remove the casing and replace the bro-
ken spring
(see chapter 5.3)
Regulator on control unit has moved
Readjust regulator
Bowl feeder develops loud noises
Cause of fault:
Fault repair
The casing has become loose
Tighten all casing screws
The magnetic coil or anchor bolt have
become loose
Tighten the screws
(see chapter 5.4)
Bowl feeder does not run at certain levels of the regulator scale
Cause of fault:
Fault repair
Potentiometer defective
Replace potentiometer
(s
ee „Controller oper-
ating instructions“)
Filled amount too large
Reduce the mass