Page 20
16/05/2019
R06.0
WARNING
Electrical work must only be carried out by trained personnel!
1.
remove the casing (1)
2.
unplug the Euro plug (2) from the control unit and disassemble
3.
loosen the cable clamp (3) and pull the cable through
4.
remove the screws (4) and exchange the magnet (5)
5.
reassemble in the reverse order
NOTE
This procedure generally includes adjustment of the air gap be-
tween the magnetic coil and the anchor bolt.
(see chapter 5.5)
Figure 6