Problem

Possible Cause / Solution

Startup

Maintenance

A) Air pump will not run or pump solution.
B) Will not draw chemical.
C) Pump runs too fast with no output.

1,3,4
1,2,3
2

5,6,9,10
6,7,8
6,7,8,9

Possible Cause / Solution

Startup

Maintenance

1. 

 Inlet ball valve partially closed or air pressure too low.

Completely open air inlet ball valve.

2. 

Chemical tube not immersed in container or container empty

Immerse tube or replenish.

3. 

Discharge ball valve closed or hose kinked

Open ball valve / Straighten the hose. 

4. 

Ice particles from condensation in air line — Air pump can
periodically "freeze up” (stall) due to ice particles in the pump's
exhaust (depending on air humidity & other factors)

WAIT several seconds to allow the ice particles to melt and blow
out, at which time the pump will automatically resume pumping.

5. 

Air regulator clogged or failed

Clean or replace.

6. 

Chemical strainer clogged up

Clean or replace.

7. 

Vacuum leak in suction line.

Tighten the connection(s).

8. 

Chemical tube stretched out where tube attaches or pin hole/cut in
tube sucking air.

Cut off end of tube or replace tube.

9. 

Problem with air pump

Refer to air pump instruction manual.

http://www.xylemflowcontrol.com/files/G57_82000-014.pdf

Replace pump.

10. 

Use of an oiler in the airline will cause pump to stall

Use only clean, dry air.

PREVENTIVE MAINTENANCE: When the unit will be out of service for extended periods, place chemical tube(s) in water and flush
the chemical out of the unit to help prevent chemical from drying out and causing build-up. Periodically check and clean chemical
strainer and replace if missing.