background image

 

5

DATA INPUT / OUTPUT CONNECTIONS 

 
Data input and output connections are located on the rear panel terminal block. A mating plug 
connector is provided.

 

The figure below identifies the specific connections for the Manchester 

and RS232 data connections for the MTX-8823C-SL.  
 

MTX-8823C-SL 

 

 

 
 
The figure below identifies the specific connections for the Manchester and RS232 data 
connections for the MRX-8823C-SL. 

MRX-8823C-SL 

 

 

 
 
DATA TERMINATION REQUIREMENTS 
 
Manchester Data Signals 

The Manchester data input on the MRX-8823C-SL is internally terminated with 120 ohms. It is 
recommended to provide a 120 ohm termination at the copper device which is terminating the 
MTX-8823C-SL data output signal. If the MTX-8823C-SL data output signal is daisy chained to 
more than one device, only the last device in the chain should be terminated. 

Summary of Contents for MTX-8823C-SL

Page 1: ...Copyright 2005 American Fibertek Inc 1222JD Instruction Manual MTX 8823C SL MRX 8823C SL Eight Channel Video Multiplexer with Return AD Bosch Manchester Code and Bi directional RS232...

Page 2: ...ion 3 Power Source 4 Power Connection 4 Fiber Connection 4 Video Input Output Connections 4 Data Configuration 4 Data Connections and Terminations 5 MTX 8823C SL Status LED Indicators 6 MRX 8823C SL S...

Page 3: ...ight independent video output signals along with the data signals This link can accommodate both a return Manchester data interface and a bi directional RS232 interface These interfaces function indep...

Page 4: ...is made via a FC PC connector located at the back of the unit Be sure to allow sufficient room for the required minimum bend radius of the fiber cable used VIDEO INPUT OUTPUT CONNECTIONS Video input a...

Page 5: ...the specific connections for the Manchester and RS232 data connections for the MRX 8823C SL MRX 8823C SL DATA TERMINATION REQUIREMENTS Manchester Data Signals The Manchester data input on the MRX 8823...

Page 6: ...are summarized below DATA 1 TX DATA 1 RX DATA 2 TX DATA 2 RX Not Used Manchester Rx RS232 Tx RS232 Rx OLI A bi color LED indicator monitors the optical input power of the data signal that is being re...

Page 7: ...bi color LED indicator monitors the power of the optical input signal that is being received at the MRX 8823C SL from video channels one through four of the MTX 8823C SL AC power and optical input st...

Page 8: ...THE FOREGOING WARRANTY THERE IS NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE EXPRESSED OR IMPLIED WHICH EXTENDS BEYOND THE WARRANTY SET FORTH IN THIS AGREEMENT In a...

Reviews: