2.Safety & Symbols
2.1 Safety Precautions
1. All work on the inverter must be carried out by qualified electricians.
2. The device may only be operated with PV panels.
3. The PV panels and inverter must be connected to the ground.
4. Do not touch the inverter cover until 5 minutes after disconnecting both DC
and AC power supply.
5. Do not touch the inverter enclosure when operating, keep away from materials
that may be affected by high temperatures.
6. Please ensure that the used device and any relevant accessories are disposed
of in accordance with applicable regulations.
7. Afore inverter should be placed upwards and handled with care in delivery. Pay
attention to waterproof. Do not expose the inverter to water, rain, snow or spray.
8. Alternative uses, modifications to the inverter not recommended. The warranty
can become void if the inverter was tampered with or if the installation is not in
accordance with the relevant installation instructions.
Safety & Symbols
02
BNT036KTL
BNT040KTL
56
61
100
100
Type
Max AC Current [A]
Rate current of AC breaker[A]
Circuit Breaker and Surge Protector Recommendation:
SPD: Lightning protection system, refer to the following options:
AC side, nominal discharge current 20KA, second grade lightning protection,
protection voltage 2.5KV
DC side, nominal discharge current 20KA, second grade lightning protection,
protection voltage 2.5KV
The wiring distance between the inverter and the distribution box should be at
least 5 meters.
Note:
The Inverter can be only connected to low-voltage grid.
(380/400/415Vac, 50/60Hz).