TROUBLESHOOTING

PROBLEM

POSSIBLE CAUSE

SOLUTION

Error Code: E1

Failure of the temperature 

sensor.

The dehumidification can function but you won't 

be able to see the temperature/humidity on the 

screen. Contact AFX Power for more assistance.

Error Code: E2

Failure of the humidity 

sensor.

Error Code: E3

Failure of the defrost sensor. Cycle power by turning the unit off and back on 

again.

Error Code: E4

Failure of the water pump.

Contact AFX Power for more assistance.

The machine is not 

positioned levelly.

Position the machine on a level surface. Turn 

power back on.

The drain hose is blocked.

Remove blockage. Turn power back on.

If any of the above solutions do not resolve the problem or issue, please contact AFX POWER at 1-877-

881-3699 to determine next steps.

Summary of Contents for EVAP

Page 1: ...o afxpower com OWNER S MANUAL WARNING To reduce the risk of injury the user must read and understand the Owner s Manual before using this product Save these instructions for future reference EVAP COMMERCIAL DEHUMIDIFIER OWNER S MANUAL ...

Page 2: ...essure psig 240 Operating Range F 33 100 Net Weight Lbs 57 Cable Length 17 Rated Current amps 4 2 Voltage 115 Hertz 50 Daisy Chain No EVAP CONTENTS Specifications 2 Safety Instructions 3 Description 4 Operation 5 Setup 5 Drain Hose 5 Control Panel 6 Buttons 6 Power 6 Time 6 Humidity Control 7 Key Lock 7 Manual Drainage 7 Defrost Indicator 7 Maintenance 7 Before Use 7 Filter Maintenance 8 Coil Main...

Page 3: ...t be tripped over To reduce the risk of fire or electric shock do not use this appliance with any solid state speed control device Do not touch this appliance or the plug with wet hands or while standing in water Do not operate the appliance near any pooled water Do not use the product in areas where gasoline paint or other flammable goods and objects are used or stored Do not insert or allow obje...

Page 4: ...R Low Grain Refrigerant Commercial Dehumidifiers are designed to maximize water extraction while combining the highest efficiency in performance and portability Latest technology and a high efficiency extraction process ensures peak performance in even the most challenging environments such as extreme temperature and low environmental humidity With high efficient water removal capacity the LGR Low...

Page 5: ...e to the Exhaust for faster drying Air Circulation It s suggested to have a constant efficient air circulation inside the area that you are going to work in for example setting up a circulation with AFX Power Air Mover combinations Environment Temperature Humidity The dehumidifier is designed to work in an environment with a temperature of 33 F to 100 F 1 C to 37 C and relative humidity level of 2...

Page 6: ...e power off by disconnecting the Power Cord from the outlet To avoid water spillage do not move the dehumidifier for at least three minutes after turning the power off TIME Press TIME to display current working time in hours and minutes For example if it displays 0000 50 it means that it has been in operation for 50 minutes To view the total working time press T once more within 10s If T is not to...

Page 7: ...matically when the reservoir is full Manual drain will last for 3 minutes 180 seconds DEFROST INDICATOR The unit begins to defrost automatically as needed when the defrost indicator lights up the unit stops defrosting when the defrost indicator is off When defrosting finishes the unit continues to dehumidify automatically MAINTENANCE Frequent maintenance is recommended on this appliance Failure to...

Page 8: ...mp then reassemble STORAGE Clean the Machine Body Use a soft damp cloth to clean the exterior of the unit Do not use any soap or solvents Do not clean the unit with water directly Organize the Power Cord and Drain Hose 1 Remove the drain hose from the drainage outlet of the machine 2 Open the velcro on the hangers 3 Hang the power cord and drain hose on the hangers and close the velcro Store the a...

Page 9: ...hed the setting level Decrease the humidity level setting set to constant dehumidification mode wait until the humidity level rises up again The machine was tilted and wasn t positioned upright for enough time before use Position the machine upright on a level surface and wait for at least 30 minutes before next use The air filter or air inlet outlet is blocked Remove blockage The environment temp...

Page 10: ...ty sensor Error Code E3 Failure of the defrost sensor Cycle power by turning the unit off and back on again Error Code E4 Failure of the water pump Contact AFX Power for more assistance The machine is not positioned levelly Position the machine on a level surface Turn power back on The drain hose is blocked Remove blockage Turn power back on If any of the above solutions do not resolve the problem...

Page 11: ...t abuse misuse or problems with electrical power supply ii Disassembling servicing or modification not authorized by AFX POWER iii Usage that is not in accordance with product instructions as stated in the Owner s Manual iv Failure to follow the product instructions or lack of necessary maintenance as described in the Owner s Manual Before contacting AFX POWER please try one or more of the followi...

Reviews: