Ag Leader Technology
DirectCommand Installation
Raven Accu-Flow ISO Kit
Page 10 of 15
February 2015
PN: 2006375 Rev. B
IMPORTANT: Prior to the use of any anhydrous toolbar with multiple
section shutoffs, consult the anhydrous cooler, plumbing
components, and manifold manufacturers to ensure that the
components have been properly selected and installed. These
manufacturer's instructions must be followed to ensure even product
distribution across the width of the toolbar. Ag Leader Technology is
not responsible for application errors resulting from improper
component design, selection, or assembly.
Note: Steps 11-13 are for systems with Control Valves that do not
have a 4 position ConXall Connector only.
11. Connect the 4 position ConXall connector of the Control Valve
Adapter Cable PN: 4001635 to the mating connector of the Flow
Control Channel Cable PN: 4003970-6.
12. Connect the 2 position molded connector of the adapter cable to
the Accu-Flow Control Valve
13. Connect the spade terminal with the black wire to the white wire
coming from the Accu-Flow Valve. Connect the spade terminal
with the red wire to the red wire coming from the Accu-Flow
Valve.
Go back to step 1.
14. Route all cables to avoid any sharp edges and pinch points.
Bundle up all excess cable and tie with zip-ties.
Installing
the ISO
Swath
Control Kit
(Optional)
Parts required for procedure:
(1) Local CAN Breakout Cable
PN: 4002567-008
(1) Liquid Swath Control Module
PN: 4002862
(1) 12 Section Boom Cable
PN: 4003949-6
Step-by-Step for
Installing the
ISO Swath
Control Kit
(Optional)
1. Mount the Liquid Swath Control Module PN: 4002862 to the
Module Mounting Plate with the Liquid Rate Control Module.
2. Plug the 24-pin FCI connector of the Local CAN Breakout Cable,
PN: 4002567-008 to the mating connector of the Liquid Swath
Control Module.
3. Connect the Local CAN Terminating Receptacle, PN: 4002871
to the mating plug of the Local CAN Breakout Cable.