background image

17

Cabinet

"Z" bracket

#8 x 

3

4

" black 

screws 

(3 places)

Figure 25

Step 7: Install the door

Carefully open the top and bottom hinges on the door being 

careful as there are many pinch points. Place the hinges 

over the 4 screws in the cabinet, 2 at the top and 2 at the 

bottom and slide the door into position. Tighten the 4 hinge 

screws with a phillips screwdriver. (See Figures 11 and 

11a). Place wire harness from the grille and mount to the 

bottom of the door with the screw and "P" clamp removed 

in step 1. (See Figure 11b). Reconnect the wire harness, 

(See Figure 12). 

SECTION A-A 

SCALE 1 : 1

LOCK

NUT

BRASS EXTENSION

CAM

PHILLIPS SCREW

13/16 COUNTER

BORE 7/16 DEEP

1/2 HOLE

3/4 INCH

WOOD PANEL

SPRING WASHER

INNER

DOOR

Step 8: Secure the cabinet

Use the #8 x 

3

4

" black screws from the literature pack to 

secure the counter top to the cabinet top through the holes 

in the cabinet "Z" bracket.

OVERLAY DOOR PANEL INSTALLATION

Figure 24

Step 6: Install lock cam

Attach the lock cam to the back of the lock assembly with 

the phillips head screw provided. Orient the lock cam verti-

cally when installing on the lock.

Cam stop

washer

Spring

washer

Cam

Set screw

Lock

Key

Retainer

nut

Screw

Brass 

extension

(2 lengths 

provided)

Step 5: Assemble lock parts

Two (2) lock extensions are provided with the lock. Use the 

longer extension for 

3

4

" thick overlay panels and the shorter 

one for 

5

8

" thick overlay panels. Assemble the lock exten-

sion, cam stop washer, spring washer, and set screw to the 

lock as shown in Figure 23 and 24.

Install this lock assembly into the lock hole in the overlay 

panel and secure with the retaining nut on the back side 

with a 15 mm socket and ratchet. Make sure the key slot in 

the front of the lock is vertical.

Figure 23

Summary of Contents for MP15BCF4 series

Page 1: ...RAP4 MP24WBG4 MP24WBF4 Built in Refrigerators Réfrigérateurs intégrées Refrigeradores empotradas EN Installation Operation and Maintenance Instructions FR Instructions d installation d utilisation et d entretien ES Instrucciones de instalación operación y mantenimiento ...

Page 2: ...red to stack products Failure to use a stacking kit could result in personal injury Contact your dealer or Aga Marvel customer service at 800 223 3900 to order For safety concerns 15 wide models should not be stacked Figure 2 Front Leveling Legs Front Grille keep this area open Leveling Legs Adjustable legs at the front and rear corners of the appli ance should be set so the unit is firmly positio...

Page 3: ... will cause the appliance to shut down GFCI s are generally not used on circuits with power equip ment that must run unattended for long periods of time un less required to meet local building codes and ordinances Electrical Connection A grounded 115 volt 15 amp dedicated circuit is required This product is factory equipped with a power supply cord that has a three pronged grounded plug It must be...

Page 4: ...he door laying on a flat surface and starting at a corner of the door remove the magnetic door gasket from the interior side of the door see Figure 13 Set the gasket aside on a flat surface There are 10 holes in the gasket retainer extrusions 3 on each side and 2 at the top and bottom which are used to fasten the panel to the front of the door The screws are provided in the literature pack along w...

Page 5: ... Hand Hinged Door 15 38 1 cm Wide Appliance 47 8 12 4 cm 327 32 9 7 cm 111 16 4 3 cm 5 12 7 cm 31 8 7 9 cm Minimum 2 5 1 cm 41 8 10 5 cm Minimum 3011 32 77 1 cm 13 16 3 cm 31 8 7 9 cm 11 2 3 8 cm typical 311 16 9 4 cm 31 8 7 9 cm Minimum This side facing interior This side facing interior 1 4 6 mm radius is permissible Hinge side of door Top of door Clearance for screw head 4 places Figure 16 Righ...

Page 6: ... 8 7 9 cm 13 4 4 4 cm 41 8 10 5 cm 1 4 6 mm radius is permissible This side to door 31 8 7 9 cm 327 32 9 8 cm 13 16 3 cm 14 35 6 cm 47 8 12 4 cm Figure 19 Left Hand Hinged Door 24 61 cm wide appliance Figure 18 Left Hand Hinged Door 24 61 cm wide appliance Hinge side of door Clearance for hinge at top and bottom Clearance for screw head 4 places 233 4 60 3 cm 13 4 4 4 cm 1 4 6 mm Deep 1 2 5 cm dia...

Page 7: ... panel is thinner than 5 8 16 mm thick shorter screws will have to be obtained Fasten the panel to the door with the 10 screws provided in the literature pack See Figure 22a Remove the clamps and replace the gasket in the gasket extrusion channels of the door Some force may be required to seat the gasket into the channels Be sure the gasket corners are seated properly Material Type 10 Wood Screw H...

Page 8: ...ws from the literature pack to secure the counter top to the cabinet top through the holes in the cabinet Z bracket OVERLAY DOOR PANEL INSTALLATION Figure 24 Step 6 Install lock cam Attach the lock cam to the back of the lock assembly with the phillips head screw provided Orient the lock cam verti cally when installing on the lock Cam stop washer Spring washer Cam Set screw Lock Key Retainer nut S...