background image

 

MERCURY Cooker Hoods: PC1000/1082/1100/1200 

 

Revision: 12/01/2015 

 

ENGLISH 

 
SECTION 1. INTRODUCTION 

Your range cooker is a semi-professional unit which gives you the power and flexibility to realise your full 

potential in the kitchen. Inevitably, during the cooking process, there will be heat, vapours and fumes 

produced. Your MERCURY extractor has been designed to complement the range cooker both in looks 
and performance in order to create the ideal environment for creative cooking.  

 
SECTION 2. EXTRACTION PERFORMANCE 

The most important influence on the  performance of the extractor is the design of the ducting which 

takes the exhaust air from the extractor to the outside wall louvre. The duct route should be a prime 
consideration during the initial stages of the kitchen design. Please note the following:  

• 

The extractor is provided with a spigot suitable for connecting 150mm diameter duct.  

• 

Note: 150mm is the minimum duct diameter consistent with efficient extraction.  

• 

The exhaust duct route length should be kept as short as possible with as few bends as possible.  

• 

The most efficient configuration is to duct straight through an outside wall so try to position the 
cooker against an outside wall when designing your kitchen layout.  

• 

The hood can be vented either to the top exhaust or the rear exhaust position. Use the position 
which gives the shortest duct route length and least number of bends. (The blower will need to be 
rotated for ducting directly through the rear exhaust position.) 

• 

A route with more than two 90 bends will significantly degrade the performance of the  extraction 
system. If possible, avoid having a 90 bend at the extractor exhaust spigot; keep bend radii as 

large as possible to maintain a smooth airflow without vortices; avoid kinks in flexible ducting; pull 
flexible ducting taut over straight runs to ensure that the internal surface is as smooth as possible. 

 
SECTION 3. IMPORTANT INFORMATION 

The following minimum headroom is required to accommodate the cooker and hood:  

For a small charge customised replacement chimneys can be produced to suit your requirements.  
The minimum distance between the range hob burners and the bottom of the extractor is essential to 
prevent overheating of the extractor and its components. 
If you are fitting a splashback then the cooker-to-hood clearance is dictated by the splashback height. 
Please also note that a 90 bend in the flexible ducting will require 215mm minimum headroom to give a 
smooth radius with no kinking. 
Requirements of the relevant authorities concerning the discharge of exhaust air must be complied with.

 

Attention:

  

This appliance requires an earth connection.  
Ensure that the supply voltage corresponds to that marked on the rating label inside the extractor. 
The extractor must be isolated from the electrical supply before carrying out any cleaning or mainte-
nance operations.  

Pay particular attention to fire risk when frying. To minimise the risk of fire, all instructions 
relating to cleaning the grease filters and removing grease deposits must be adhered to.  
Do not flambé under the extractor. 

 
SECTION 4. INSTALLATION 
4.1 Removing the Grease Filter(s) 

Place extractor on its backplate on a horizontal surface. 
To remove the grease filters pull/lift the filter release lever away from the hood base. This releases the 

retaining clips allowing the filter to be carefully lifted away from the hood. Take care not to scratch the 
hood. 
The internal fixing holes, blower assembly and spigot blanking plate can now be accessed through the 
openings in the baseplate. (See Page 7). 

4.2 Blower Exhaust Position 

The hood can be vented either to the top exhaust or the rear exhaust position. Each exhaust position 
has 4 studs onto which can be bolted either the blower assembly or a blanking plate. 
Bolt blower assembly to chosen exhaust position and the blanking plate to the unused position. 
When changing the exhaust position, care should be taken not to excessively pull or twist the cable 
attached to the blower. 

4.3 Duct Installation 

Make a hole in the wall or ceiling to take the 150mm diameter ducting from the extractor exhaust spigot 
to the outside. 
The exhaust duct route length should be kept as short as possible with as few bends as possible - see 
Section 2. 
Knock a hole in the outside wall to match the internal measurements of the louvre. 

4.4 Fixing the Hood to the Wall  

If you are fitting a Splashback it must be fitted before the hood. 

Instructions for mounting the hood are given on page 7 

Note:

 The decorative chimney can be removed to ease handling of the hood. 

The supporting wall must be of good quality, have an even surface and be sturdy enough to support the 
extractor. 
Fixings must be used which are suitable for the type of wall construction. 

4.5 Connecting the Ducting  

Connect ducting to extractor exhaust spigot. This may have to be done prior to fixing the extractor to the 

wall. You may find this easier with the chimney removed. The chimney is attached using M4 machine 
screws which can be accessed through the filter opening(s). 
When the extractor is in position, check that the duct has not been flattened or kinked along its route. 
Connect the ducting to the wall louvre spigot or alternative outside termination. 
Secure the louvre to the outside wall. Ensure that any air fins are directed downwards.  
Refit the grease filter(s). 

4.6 Electrical Installation  

The extractor is a stationary appliance designed to be connected by fixed wiring to the electrical supply.

 

A competent electrical technician must perform the electrical installation. 
The extractor must be fed from a 230Vac single phase electrical supply using a switched spur fitted with 

a 3A fuse. The spur should be located adjacent to the extractor/cooker so that the supply can be discon-

nected from the extractor using the switch. The means of disconnecting from the supply must have a 

minimum contact separation of 3mm in all poles. Alternatively a means of disconnection in the fixed 
wiring according to the relevant wiring rules must be fitted.  
A supply cord for connecting the spur to the extractor is included. 
The mains supply is connected to the free end of this cord as follows:

 

 

 
SECTION 5. OPERATING INSTRUCTIONS 

Switch power on at the fused spur. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
SECTION 6. MAINTENANCE

 

Regular maintenance is essential to ensure good performance and long-life. 
To clean the stainless steel surfaces of the extractor use a proprietary cleaning agent. Do not use 

abrasive cleaning materials or products. 
Clean the grease filters in a dishwasher or by hand-washing in hot water and detergent.  Wash the filters 

at least every 2 months - sooner if the extractor is used extensively. 
To remove the grease filters pull the chrome effect filter release lever away from the hood base. This 

releases the retaining clips allowing the filter to be carefully lifted away from the hood. Care should be 

taken not to scratch the hood.  
To maintain the immaculate appearance of the extractor, and to minimise fire risk, ensure that grease 

deposits on the extractor surfaces are kept to a minimum by regular cleaning. 
LED lamps require no end user maintenance. 
  

SECTION 7. SPECIFICATIONS 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

Hood Weights 

(Approximate) 

 

Cooker-to-hood clearance (min):

 

800 mm

 

Hood height including chimney:

 

511—762 mm

 

Minimum ceiling height with standard chimney:

 

2251mm

 

Warning 

Proper care must be taken to ensure that the negative pressures caused by high performance 

extraction systems do not adversely affect the safe operation of certain types of fuel-burning 

appliances (gas, oil or solid fuel), including those installed in the kitchen and possibly also those 

installed in other parts of the house. 
Where such fuel-burning appliances are installed, adequate ventilation MUST be provided in the 

room of installation, located and sized such that the negative pressure in the room created by the 

extractor does not exceed 4Pa. 
In case of doubt, do not operate the extractor and fuel-burning appliance(s) simultaneously and 

consult an appropriate (for the fuel type) expert for advice.  

The exhaust air must not be discharged into a flue which is used for exhausting fumes from appli-

ances supplied with energy other than electricity, e.g. oil or gas-fired central heating boilers, gas-

fired water heaters, etc. 

Adequate ventilation of the room must be provided when the cooker, extractor and appliances 

supplied with energy other than electricity (e.g. gas-fired or oil-fired heaters, etc.) are used simulta-

neously. The room must be provided with vents to allow a constant flow of fresh air.  

ELECTRICAL HAZARD 

DISCONNECT ELECTRICAL SUPPLY 

BEFORE PROCEEDING FURTHER

 

INCOMING SUPPLY CORD CONNECTIONS

 

Core

 

Core Colour

 

Live 

Brown 

Neutral 

Blue 

Protective Earth 

Green/Yellow 

PC1000

 

28Kg

 

PC1082/1100

 

29Kg

 

PC1200

 

29.5Kg

 

Pushbutton Functions 

 

 

 

 

 

 

 

 

 

 

 

 

 

The extractor controller will automatically switch off the appliance if there has been 
no operator action for 4 hours. 

After 30 hours accumulated running GREASE FILTER CLEANING will be signalled by all 6 
indicators flashing. Reset by pressing Push-button FAN OFF (delay). 

Lights ON/OFF 

Motor ON - SPEED 1 

Motor – TIMED INTENSIVE MODE (Reverts automatically to speed 3 after 5 mins) 

Motor ON - SPEED 3 (Maximum Speed for Continuous Use) 

Motor ON - SPEED 2 

Motor RUN ON TIMER (OFF after 10 minutes to clear fumes) 

Blower airflow, nominal:

 

800 m

3

/hr

 

Supply voltage:

 

230V~ 50Hz

 

LED lamp voltage:

 

12V

 

Blower power input:

 

1 @ 275W

 

Lamp power:

 

2 x 2.6W

 

Fuse size for electrical supply:

 

3A

 

Blower spigot diameter:

 

150mm

 

For detailed specification and energy 

efficiency information please refer to the 

product fiche for your hood. 

Summary of Contents for MERCURY PC1000

Page 1: ... Installations danvändnings och underhållsanvisningar Clarence Street Royal leamington Spa Warwickshire CV31 2AD England Tel 44 0 1926 457400 Fax 44 0 1926 450526 E mail consumers agarangemaster co uk www mercury appliances co uk Customer Services 0870 789 5107 Technical Queries 0870 589 5105 NEDERLANDS 5 Instructies voor montage gebruik en onderhoud EN FR DE NL SV 7 HOOD DIMENSIONS and FIXING HOL...

Page 2: ...actor Fixings must be used which are suitable for the type of wall construction 4 5 Connecting the Ducting Connect ducting to extractor exhaust spigot This may have to be done prior to fixing the extractor to the wall You may find this easier with the chimney removed The chimney is attached using M4 machine screws which can be accessed through the filter opening s When the extractor is in position...

Page 3: ...omment raccorder le conduit Fixez le conduit à l adaptateur Il se peut qu on soit obligé de le faire avant de fixer le ventilateur contre le mur Il est conseillé d enlever la partie décorative avant cette manœuvre La cheminée est attachée en utilisant des vis machine M4 qui peuvent être accédés par la les ouverture s à filtre Quand le ventilateur est en place vérifiez que le conduit ne soit pas ap...

Page 4: ...tigungselemente benutzt werden 4 5 Abluftschachtanschluss Den Schacht mit dem Abluftstutzen der Dunstabzugshaube verbinden Dies muss vielleicht vor dem Anbringen der Dunstabzugshaube an der Wand durchgeführt werden Dies fällt mit entferntem Kamin leichter Der Kamin ist mit M4 Maschinenschrauben befestigt und kann durch die Filteröffnung en erreicht werden Nach Ausrichtung der Dunstabzugshaube sich...

Page 5: ...ina 7 Let op de decoratieve schacht kan verwijderd worden De afzuigkap is dan beter hanteerbaar Overtuig u dat de muur glad en sterk genoeg is om de afzuigkap aan op te hangen Gebruik de juiste bouten om de afzuigkap op te hangen 4 5 Montage van de Afvoer Bevestig de afvoerslang aan de manchet op de afzuigkap Bij aansluiting aan de achterzijde van de afzuigkap voor ophanging eerst de afvoerslang b...

Page 6: ...derlätta hanteringen av kåpan Väggen där kåpan fästs måste vara av god kvalitet ha en jämn yta och vara tillräckligt kraftig för att bära fläktkåpan Fästelement som passar väggtypen måste användas 4 5 Ansluta trumman Anslut trumman till fläktkåpans utlopp Vid utlopp bakåt kanske detta måste göras innan fläktkåpan fästs på väggen Det kan vara lättare om skorstenen är borttagen Den är fäst med M4 sk...

Page 7: ...de 1 Eine waagerechte Linie Linie A an der unteren Kante der Haube markieren wenn bereits ein Spritzschutz angebracht wurde kann dessen obere Kante verwendet werden 2 Eine senkrechte Mittellinie von Herd und Haube markieren Linie B 3 Die Positionen von Montagelöchern wie oben beschrieben markieren Tipp Die Haube an die gewünschte Position halten und die Wand durch die Montagelöcher in der Rückwand...

Reviews: