The Severn Stove with boiler is designed to provide space
heating and the heating of domestic hot water and
radiators and has been approved by the Domestic Solid
Fuel Appliance Approval Scheme.
The appliance and burning rate are controlled by the
manual adjustment of the appliance thermostat only.

The recommended heating surface area is based on an
average heat emission of 0.5kW/m

(160 Btu/h/ft

2

).

These figures are maxima and must not be exceeded.

A margin (about 10% or 1.4m

2

- 15ft

2

) is recommended.

10/00 EINS 33713

1

Installation Instructions
for Freestanding Severn Stove
with Boiler

Consumer Protection Act 1987

As manufacturers and suppliers of cooking and heating products, in
compliance with Section 10 of the Consumer Protection Act 1987,
we take every care to ensure as far as is reasonably practicable, that
these products are so designed and constructed as to meet the
general safety requirement when properly used and installed. To this
end, our products are thoroughly tested and examined before
despatch.

IMPORTANT NOTICE:

Any alteration that is not approved by Aga-Rayburn,

could invalidate the approval of the appliance, operation of the warranty and
could also affect your statutory rights.

Control of Substances - Health and Safety
Important

This appliance may contain some of the materials that are indicated
below. It is the Users/Installers responsibility to ensure that the
necessary personal protective clothing is worn when 

handling, where applicable, the pertinent parts that contain any of
the listed materials that could be interpreted as being injurious to
health and safety, see below for information.

Firebricks, Fuel beds, Artificial Fuels

- when handling use

disposable gloves.

Fire Cement

- when handling use disposable gloves.

Glues and Sealants

- exercise caution - if these are still in liquid

form use face-mask and disposable gloves.

Glass Yarn, Mineral Wool, Insulation Pads, Ceramic Fibre,
Kerosene Oil

- may be harmful if inhaled, may be irritating to skin,

eyes nose and throat. When handling avoid inhaling and contact with
skin or eyes. Use disposable gloves, face-masks and eye protection.
After handling wash hands and other exposed parts. When disposing
of the product, reduce dust with water spray, ensure that parts are
securely wrapped.

THE SEVERN

WARNING

BOILER MODEL

UNDER NO CIRCUMSTANCES MUST THE

APPLIANCE BE FIRED DRY AS DAMAGE 

WILL OCCUR

PERFORMANCE

RATING

Direct Space Heating

Water Heating

Direct Space Heating

Pipe and radiator surface
(no domestic hot water)

Radiator Surface (with
domestic hot water)

The maximum room size (of normal construction) and
radiator surface that can be heated are:-

Solid Fuel

Wood

kW

2.9

2.9

7.1

53.8

1900

14.5

156

12.1

130

10.2

53.8

1900

20.9

225

18.6

200

kW

m

3

ft

2

m

2

ft

2

m

2

ft

2

NOTE: THERE ARE TWO SETS OF BACK OUTLET

‘FLOW AND RETURN’ CONNECTIONS ON THE L.H.

AND R.H. SIDE OF THE BOILER.

THE STOVE CAN BE INSTALLED AS A TOP OR BACK

FLUE APPLIANCE 

Summary of Contents for THE SEVERN

Page 1: ...allers responsibility to ensure that the necessary personal protective clothing is worn when handling where applicable the pertinent parts that contain any of the listed materials that could be interpreted as being injurious to health and safety see below for information Firebricks Fuel beds Artificial Fuels when handling use disposable gloves Fire Cement when handling use disposable gloves Glues ...

Page 2: ...n not operate until the temperature exceed 50 C and power is restored 3 All installations must be fitted with a drain tap at the lowest point of the system For correct operation of the appliance the height of the chimney from its base should not be less than 5 5m and terminate above the roof in accordance with current Building Regulations and requirements as outlined in BS 6461 Part 1 and BS 7566 ...

Page 3: ...n Holes will be required in one or both sides of the pipework The clearance between the appliance and any combustible material must be maintained as indicated in Figs 1a 1b 2a 2b and 3 A permanent unobstructed air vent is required having a minimum effective area of 83cm2 and communicating directly to outside air or an adjacent room which itself has a permanent air vent direct to outside air Effect...

Page 4: ...4 ...

Page 5: ... locks i When lighting open both firedoors and place paper and sticks with a small quantity of fuel onto the bottomgrate Ignite paper and set the thermostat knob to 8 high and lock both firedoors When established balance the water system ii With the appliance under fire check for soundness of seals joints and that the flue functions correctly in permitting all smoke and fumes to be vented through ...

Page 6: ...6 ...

Page 7: ...7 ...

Page 8: ...s policy of continuous product improvement the Company reserves the right to change specifications and make modifications to the appliance described and illustrated at any tim Manufactured By Aga Rayburn Station Road Ketley Telford Shropshire TF1 5AQ www aga rayburn co uk www agacookshop co uk ...