3
INSTALLATION
INSTALLATION SECTION
With specific exceptions, the installing of any type of AGA cooker is subject to the respective directions contained in current
issue of the Building Regulations. In addition, planning permission may need to be obtained, which should be applied for
separately.
The complete cooker is floor-mounted and the space in which the appliance is to be fitted must have the following minimum
dimensions:-
A 3mm gap is required each side between the cooker top plate and adjoining work surfaces that maybe fitted, this is to
allow for the safe removal of the top plate, should this be required at a later date.
Where cookers are fitted against side walls which protrude beyond the front of the AGA, a 116mm clearance is required
at the RH side for oven doors access.
If the AGA is to be installed in a brick recess, then the minimum clearance should be increased by at least 10mm on either
side, to allow for the walls not being square and also for the natural dimensional variations found in the castings.
In addition, a minimum clearance of 1000mm must be available at the front of the cooker to enable the cooker to be
serviced.
NOTE:
AGA COOKERS ARE DELIVERED EX-WORKS UNASSEMBLED. ASSEMBLY IS UNDERTAKEN BY THE
AUTHORISED AGA DISTRIBUTOR/SPECIALIST.
Cooker Base or Hearth
It is essential that the base or hearth on which the cooker stands should be level and be capable of supporting the total
weight of the cooker.
Model EC - 406 kg
Model EE - 584 kg
Consumer Protection
As responsible manufacturers we take care to make sure that our products are designed and constructed to meet the
required safety standards when properly installed and used.
IMPORTANT NOTICE: PLEASE READ THE ACCOMPANYING WARRANTY
Any alteration that is not approved by AGA could invalidate the approval of the appliance, operation of the warranty and
could also affect your statutory rights.
In the interests of safety and effective use, please read the following before using your new AGA appliance.
Important
This appliance may contain some of the materials that are indicated. It is the Users/Installers responsibility to ensure that
the necessary personal protective clothing is worn when handling, where applicable, the pertinent parts that contain any
of the listed materials that could be interpreted as being injurious to health and safety, see below for information.
Fire Cement
- when handling use disposable gloves.
Glues and Sealants
- exercise caution - if these are still in liquid form use face mask and disposable gloves.
Glass Yarn, Mineral Wool, Insulation Pads
- may be harmful if inhaled, may be irritating to skin, eyes, nose and throat.
When handling avoid inhaling with skin or eyes. Use disposable gloves, face-masks and eye protection. After handling
wash hands and other exposed parts. When disposing of the product, reduce dust with water spray, ensure that parts are
securely wrapped.
Since this appliance can be used continuously, please take note of these
IMPORTANT
instructions:
Combustible Walls
Houses constructed of combustible materials (such as all-timber or stud wall partitions and batoned plasterboarded
walls) require special wall heat protection features.
Non-combustible walls behind a cooker must be of at least 25mm thick insulation board (Monolux or equivalent), up to
hotplate level.
In addition, oven vent piping must be insulated with the high temperature film glass sleeving, supplied, and a 25mm gap.
SPECIAL NOTE:
Ensure electric cabling or plastic services do not pass within or on the outside of the wall, behind or
directly above the cooker. This type of material can age prematurely when exposed to continuous higher ambient
temperature.
Summary of Contents for EC-LMV
Page 7: ...7 OVEN VENT PIPE CONNECTION OPTIONS Fig 3 DESN 513987 ...
Page 9: ...Fig 4 Fig 5 Fig 6 DESN 513937 DESN 513938 DESN 516111 9 ...
Page 17: ...17 ...
Page 18: ...18 ...
Page 19: ...19 ...