4
The top of the hearth must be of non-combustible material thickness of 12mm.
The wall behind the cooker must be of non-combustible material for a minimum thickness of 25mm.
If the oven vent pipe passes through combustible material, there must be an airgap of at least 25mm around the pipe
preferably wrapped with insulation material.
The appliance oven venting pipe can be achieved up to a maximum length of 6 metres, through an outside wall or unused
flue etc. Great care must be taken in all-timber houses.
Tiling
When the cooker is to stand in a recess, or against a wall which is to be tiled, in no circumstances should the tiles overlap
the cooker top plate.
Installation Requirements
The installation of the cooker must be in accordance with the relevant requirements of the IEE Wiring Regulations and
Building Regulations.
It should be in accordance also with any relevant requirements of the local authority.
In your own interest, and that of safety to comply with the law, all appliances should be installed by an authorised AGA
distributor, in accordance with the relevant regulations.
A
B
C
D
F
G
H
K
L
M
N
R
116
T
V
W X
Y
Z
mm 987 889 851 679 1330 756 1125 3 698 484 816
52 790 873 55 699 662
Fig. 1
EC-LMV MODEL
*
THIS HOLE IF REQUIRED FOR OVEN VENT PIPE IS TO BE CUT ON SITE IN THE LEFT OR
RIGHT HAND SIDE PANEL.