Clearance to Combustible & NON Combustible Materials
Reference Point
Minimum Clearance
from Combustible
Materials
Minimum Clearance
from Non Combustible
Materials
Either Side of the Stove
550mm
100mm
Rear of the Stove to the Wall
350mm
100mm
Top of the stove to the underside
of the Mantel
As defined by the latest Local
Building Regulations
As defined by the latest Local
Building Regulations
Hot Zone to the Outside of the
Front Door of the Stove
Allow 1000mm to the front as
this area gets HOT
Allow 1000mm to the front as
this area gets HOT
Diagram for illustration
purposes only - Not to Scale
Please Note - In the Hot zone at the front of the stove, do not place to dry laundry as if could
cause a FIRE, if children, the elderly or persons with limited mobility
are in the room unoccupied
a Fire Guard must be installed
3.4 Appliance Fireplace Installation
Determine the position required for the appliance.
Create a gas connection for the appliance in approximately the correct location for the gas controls. With
a cut off valve and pressure test point
The gas controls are connected to the Burner of the appliance. (Factory Fitted)
This appliance has adjustable feet, these must me set to the desired length before the flue position is
finalised. Fine adjustment of the legs is available via the feet.
Do not make any adjustments to the appliance, except the adjustment in the bolts to level the stove if
required.
The appliance should be fitted with a minimum clearance as defined in the table above from any
combustible objects or materials; this includes any combustible materials used for the fireplace
construction. This clearance distance can be reduced to 300mm if a Cement Board, of minimum
thickness 12mm is used. This Cement Board will act as a Thermal Break.
The clearance distance of the Flue from combustibles must not be less than 350mm. This dimension
can be reduced to 300mm as the distance from the underside and the sides of Horizontal Flue runs.
As this is a room sealed appliance and the appliance stands on appropriate legs, a hearth is not required
for this appliance. But would be a requirement when being fitted to a combustible floor surface such a
carpet, wooden or laminate flooring
If a shelf is to be fitted above the fireplace opening, a gap (as defined by local building Regulations must
be adhered to) should be left between the opening and the shelf.