48
AGA Ellesmere Standard Gas Stove
Appendix 2 -
Appliance Commissioning Checklist & Customer Sign Off
Section 1 to 3 - to be completed by the Gas Safe Engineer
Section 4 & 5- to be completed by the Customer & the Gas Safe Engineer
SECTION 1 - FLUE CHECKLIST
YES
NO
Is the Flue correct for appliance? All Locking Bands fitted?
Has the flue been checked for Leaks?
Have the inner and outer Flue Collars been fitted correctly & gasket seals all ok?
Has a Wire Basket been fitted to the outside Horizontal Terminal on the wall?
SECTION 2 - GAS CHECKLIST
Please write
in here the
Mbar
Measured
YES
NO
Gas soundness
– All joints fully tested?
N/A
ON/OFF Tap with Pressure Check Point be fitted?
N/A
Standing Gas Pressure (Mbar)
– Inlet Pressure?
Appliance Burner Working Pressure (
on HIGH FLAME Setting
– HOT
Stove
) NB All other gas appliances must be operating on full (Mbar)?
Pilot Assembly & thermocouple all checked & working correctly?
N/A
SECTION 3 - SAFETY CHECKLIST
YES
NO
Glass checked to ensure no damage, scratches, scores, fingerprints or cracks?
Inner glass frame secured correctly & QTY 6 x screws replaced, seal fitted either side of
glass all ok?
Ceramic Logs and embers have been fitted correctly?
– Not covering the thermocouple
area?
Relief Valve Flap (RVF) on the top of the stove & gasket are fitted correct and RVF is
fully closed position?
GV 60 Valve Control Dial is clicked into the ON Position?
Receiver Unit is fully fitted into the Silver Heatproof Housing & the wiring loom is all
secure?
Anti tip forward Chain Fitted? & Screw to lock the flue pipe to the collar fitted?
SECTION 4 - CUSTOMER HAND OVER CHECKLIST
YES
NO
Customer fully understands how to use the remote control?
Customer understands all of the function of the Stove?
Customer is given this copy of the Operating Manual?
Customer understands how to fit new batteries into the battery pack at the rear of the
stove?
Customer Understand where the gas shut off valve is installed for the stove?
Customer has no issues with the stove?
SECTION 5 - CUSTOMER SIGN OFF
GAS SAFE ENGINEER SIGN OFF
Customer Name:
Customer Signature:
Date:
Gas Safe Engineer Full Name:
Gas Safe Engineer Signature:
Date:
Gas Safe Engineer Registration Number: