Note:-

If there is any work that is being carried out

that would effect the air quality supplied to the stove
such as sanding a floor or glueing linoleum etc. the
stove must be out of operation. The dust or vapours
may be a potential hazard, the air supply and local
area needs to be thoroughly ventilated before
putting the stove in operation again.

Extractor Fan

There must not be an extractor fan fitted in the same
room as the stove as this can cause the stove to
emit smoke and fumes into the room.

COMMISSIONING & HANDOVER

On completion of the installation allow a suitable
period of time for any fire cement and mortar to dry
out, when a small fire may be lit and checked to
ensure the smoke and fumes are taken from the
stove up the chimney and emitted safely to the
atmosphere. 

Do not run at full output for at least

24 hours.

On completion of the installation and commissioning
ensure that the operating instructions for the stove
are left with the customer. Ensure to advise the cus-
tomer on the correct use of the appliance with the
fuels likely to be used on the stove and warn them to
use only the recommended fuels for the stove.

Advise the user what to do should smoke or fumes
be emitted from the stove. The customer should be
warned to use a fire guard to BS 8423:2002 in the
presence of children, aged and/or infirm persons.

LOCATION

There are several conditions to be considered in
selecting a location for your stove.

A. Allowances for proper clearances to 

combustibles of the stove and flue pipes.

B.  The product must be installed on a non 

combustible hearth with adequate load bearing 
capacity.

C. Fluing considerations;  length of flue, length of 

horizontal run, flue termination.

D. Location within area to be heated.

FLOOR PROTECTION

The product must be placed on a non combustible
hearth in accordance with UK Building Regulation
part ADJ. The hearth must be suitably robust and to
the appropriate dimensions.

For free standing installations it is acceptable to
place the stove on a  solid sheet of non combustible
material minimum 12mm thick, as the product will
not raise the temperature of the upper surface of the
hearth up to 100 

o

C. 

CLEARANCE TO COMBUSTIBLES - 
(No Heatshield)

Side wall to stove 

28” 700mm

Back wall to stove

28” 700mm

Corner

25” 635mm

Mantle clearance 

25” 635mm

It is recommended that this appliance is sited next to
and on a non-combustible surface.  A minimum all
round clearance of 150mm will allow air circulation
and not impede the performance of the stove. See
Figs 3a, 3b, 3c & 3d.

Fig.3a

Fig.3b

Fig.3c

Fig.3d

Summary of Contents for ELLESMERE 4K

Page 1: ...n aged or infirm persons should be supervised at all times and should not be allowed to touch the hot working surfaces while in use or until the appliance has thoroughly cooled When using the stove in situations where children aged and or infirm persons are present a fireguard must be used to prevent accidental contact with the stove The fireguard should be manufactured in accordance with BS 8423 ...

Page 2: ...stibles 5 14 Stove Dimensions 7 15 Technical Data 8 16 Air Controls 9 17 Recommended Fuels 9 18 Riddling 10 19 Refuelling 10 Refuelling onto a low firebed 10 Fuel overloading 10 Operation with door left open 10 20 Dampers Air Controls left open 10 21 De Ashing 10 22 Disposal of Ash 10 23 Maintenance 11 24 Chimney Cleaning 11 25 Important Notes 11 26 Lighting 12 27 Fire Safety 12 28 CO Alarms 13 29...

Page 3: ...r is installed by a Competent Person registered with a Government approved Competent Persons Scheme HETAS Ltd operate such a Scheme and a listing of their Registered Competent Persons can be found on their website at www hetas co uk The installation must be completed in accordance with current National and European Standards and Local Codes It should be noted that the requirements and these public...

Page 4: ...he flexible flue liner The chimney flue should be designed to allow for cleaning of the stove use pipes with cleaning doors where necessary Avoid the use of 90 degree elbows use 2 x 45o bends instead Horizontal runs of flue pipe should be avoided where it is unavoidable the maximum permitted horizontal run is 150mm The chimney flue must have the necessary clearance distance from combustible materi...

Page 5: ... for when determining the effective free area of any vent Air vents direct to the outside of the building should be located so that any air current produced will not pass through normally occupied areas of the room An air vent outside the building should not be locat ed less than the dimensions specified within the Building Regulations and B S 8303 Part 1 from any part of any flue terminal These a...

Page 6: ...o should smoke or fumes be emitted from the stove The customer should be warned to use a fire guard to BS 8423 2002 in the presence of children aged and or infirm persons LOCATION There are several conditions to be considered in selecting a location for your stove A Allowances for proper clearances to combustibles of the stove and flue pipes B The product must be installed on a non combustible hea...

Page 7: ...REDUCED CLEARANCE TO COMBUSTIBLES With Heatshield See Figs 4a 4b 4c Fig 4a Fig 4b Fig 4c 6 Side wall to stove 28 700mm Back wall to stove 28 700mm Corner 25 635mm Mantle clearance 25 635mm ...

Page 8: ...7 STOVE DIMENSIONS Fig 5 Note Dimensions stated are in milimeters and may be subject to a slight variation 4kW 6kW 5kW ...

Page 9: ...peration e g intensive burning high fuel consumption and can also lead to permanent damage to the stove ELLESMERE STOVES TECHNICAL DATA 4 kW 5kW 6kW FUEL WOOD ANCIT WOOD ANCIT WOOD ANCIT Nominal Output Room 4 5 3 8 5 2 5 0 5 9 6 4 Typical refuelling intervals to obtain nominal outputs Hour 75 1 75 1 75 1 Fuel Gas Mass Flow g s 3 3 2 7 4 3 9 4 3 9 Flue Gas Temp at Nominal Output oC 263 190 263 245 ...

Page 10: ...re to provide a little primary to maintain the fire When burning coal the air control should always be to the right of centre On initial light up the lever should be pushed slightly to the right and pushed fully in providing under grate air fully while still pro viding some window wash air to maintain a clear viewing glass See Fig 6 To engage the operating tool onto the air control rotate the tool...

Page 11: ... on the left side of the stove While keeping the tool pushed in rotate in a circular motion which will cause the individual grate castings to rise and fall dislodging the ash into the ashpan See Fig 9 Remember to reset the controls after refuelling DAMPERS AIR CONTROLS LEFT OPEN Operation with the air controls or appliance dampers open can cause excess smoke The appliance must not be operated with...

Page 12: ...ick Lift the stainless steel baffle and catch a back brick on the top edge and tilt it forward to remove it Lift and hold the stainless steel baffle while catching the remaining back brick on the top edge and tilting it forward to remove it 11 WARNING NOTE Properly installed operated and maintained the stove will not emit fumes into the dwelling Occasional fumes from de ashing and re fuelling may ...

Page 13: ...S LIGHTING Before lighting the stove check with the installer that the installation work and commissioning checks described in the installation instructions have been carried out correctly and that the chimney has been swept clean is sound and free from any obstructions As part of the stoves commissioning and handover the installer should demonstrate how to operate the stove correctly WARNING The ...

Page 14: ...baffle on the right hand side while holding it up catch the top edge of the right hand side brick and lower it into the stove to allow for removal Remove the cast iron baffle cleaning door by lifting it forward while sliding it to the right clear of the left hand side brick this will allow the back edge be low ered so the baffle is almost vertical allowing it be manoeuvred through the door opening...

Page 15: ...ve the broken glass c Clean the glass recess in the door d Place the glass into the door recess and replace the four corner clips e Tighten screws f Replace glass only with ceramic glass 5mm thick PROLONGED PERIODS OF NON USE If the stove is to be left unused for a prolonged peri od of time then it should be given a thorough clean to remove ash and unburned fuel residues To enable a good flow of a...

Page 16: ... PLATE 177A_0000_161 14 HINGE PIN STOP 177A_0000_171 15 SHELL BRACKET 177A_0000_181 16 ASHPIT COVER 177A_0000_211 17 RIDDLING ROD RETAINER 177A_0000_221 18 STOVE SHELL 177A_0100_001 19 FIRE DOOR 177A_0300_011 20 HINGE LINK 177A_0300_021 21 DOOR LATCH 177A_0300_041 22 GLASS 177A_0300_051 23 GLASS CLIP 177A_0300_061 24 DOOR HANDLE 177A_0300_071 25 WASHER 177A_0300 _081 26 HOB 177A_0600_001 27 RIDDLI...

Page 17: ... PLATE 177A_0000_161 14 HINGE PIN STOP 177A_0000_171 15 SHELL BRACKET 177A_0000_181 16 ASHPIT COVER 177A_0000_211 17 RIDDLING ROD RETAINER 177A_0000_221 18 STOVE SHELL 177B_0100_001 19 FIRE DOOR 177B_0300_011 20 HINGE LINK 177B_0300_021 21 DOOR LATCH 177A_0300_041 22 GLASS 177B_0300_051 23 GLASS CLIP 177A_0300_061 24 DOOR HANDLE 177A_0300_071 25 WASHER 177A_0300 _081 26 HOB 177B_0600_001 27 RIDDLI...

Page 18: ... PLATE 177A_0000_161 14 HINGE PIN STOP 177A_0000_171 15 SHELL BRACKET 177A_0000_181 16 ASHPIT COVER 177A_0000_211 17 RIDDLING ROD RETAINER 177A_0000_221 18 STOVE SHELL 177A_0100_001 19 FIRE DOOR 177C_0300_011 20 HINGE LINK 177B_0300_021 21 DOOR LATCH 177A_0300_041 22 GLASS 177A_0300_051 23 GLASS CLIP 177A_0300_061 24 DOOR HANDLE 177A_0300_071 25 WASHER 177A_0300 _081 26 HOB 177C_0600_001 27 RIDDLI...

Page 19: ...ating Replace the grate and do not allow ash pan to overfill Operation with the ash door open While the stove is in operation the door should be closed Burning non approved fuel Burn correct fuel Glass Sooting Up Air wash not working Open the air wash control Moisture content of fuel too high Ensure fuel is sufficiently dry Insufficient flue draught Seek professional chimney advice Air controls se...

Page 20: ...nstallation Final cure of the painted surfaces This odour is unpleasant but not toxic It is best advised to ventilate the room and leave unoccupied Incorrect sealant used All flue Joints must be sealed with fire cement only Insufficient flue draught Seek professional chimney advice Water In Base Of Stove Condensation on light up It is acceptable to have a little condensa tion on start up when the ...

Reviews: