THESE INSTRUCTIONS SHOULD BE LEFT

WITH THE APPLIANCE AND THE USER TO RETAIN
FOR FUTURE REFERENCE.

Aga Gas Fired ranges are delivered unassembled.
Before installation can be made the site is inspected for
suitability by an Authorised Aga Distributor and corrected
where necessary to conform with local installation codes
or in the absence of local codes with:

In Canada:

The CAN/CGA-B149 installation codes.

In U.S.:

The National Fuel Gas Code ANSI Z223. 1-latest edition.

Assembly is undertaken on site by the same Aga
Distributor to ensure correct performance and safety.

It is essential that the base or hearth on which the range
stands should be level and strong enough to support the
weight of the range.

Approximate weights:-

Models GC (Open Flue) and GC (Direct Vent)
- 408kg (900lb)
Models GE (Open Flue) and GC (Direct Vent)
- 585kg (1290lb)

The top face of the hearth must be of non-combustible
material for a minimum thickness of 12mm (1/2in) and
comply with current Building Regulations and National
Fire Laws.

The wall behind the cooker draft hood and flue connector
must have a minimum air gap of 57mm (2 1/4”). Any
openings in the wall behind the range or in the floor under
the range must be sealed before appliance installation.
Ensure the draft hood is securely bolted to the support
spigot as shown in Fig. 2.
NOTE: THIS IS NORMALLY FITTED AND SECURED BY
THE FACTORY BEFORE DESPATCH.

The wall behind the range must be the outside wall for
the venting of flue products. Wall thickness between
150mm (6 in) and 355mm (14 in) can be catered for at the
same time as site inspection.
Alternatively, special lengths can be offered to order up to
a maximum of 610mm (24 in) long.

Open Flue - Models GC and GE

Installation Instructions for Aga Gas Fired Range
Models:

GC Open Flue Range (2 Oven)
GC Direct Vent Range (2 Oven)
GE Open Flue Range (4 Oven)
GE Direct Vent Range (4 Oven)

For U.S. and Canadian Markets

1

04/08 EINS 33644

BASE OR HEARTH

OPEN FLUE RANGE -
MODELS GC AND GE

DIRECT VENT RANGE-

MODELS GC AND GE

Summary of Contents for GC Open Flue Range

Page 1: ...rial for a minimum thickness of 12mm 1 2in and comply with current Building Regulations and National Fire Laws The wall behind the cooker draft hood and flue connector must have a minimum air gap of 5...

Page 2: ...ng types of vent i Type B Vent 25mm 1in minimum ii Single wall vent connector 150mm 6in minimum Listed connectors passing through combustible walls and partitions must be guarded by a ventilated metal...

Page 3: ...ly from the bottom of an openable window air vent or any other ventilating opening b Within 300mm 12in above adjacent ground level c Within 600mm 24in of any surface facing the terminal d Within 355mm...

Page 4: ...ly piping system at test pressures equal to or less than 1 2 psig 3 5kPa The model and serial numbers for this appliance are found on the name plate These numbers must be used when requesting advice f...

Page 5: ...tablished release the control knob gradually and rotate anti clockwise to its low fire position whereupon the main burner will light Leave in the low fire position for at least 30 minutes NOTE Any att...

Page 6: ...ows Description 1 Pilot Thermocouple 2 Main Burner 3a Pilot Burner Assembly N G 3b Pilot Burner Assembly L P G 4 Combination Gas Valve 5a Pressure Regulator N G 5b Pressure Regulator L P G 6 Combustio...

Page 7: ...7 Fig 12 Pilot Thermocouple DESN 512827...

Page 8: ...he PTFE insulation cable remains intact and strip is firmly connected to the spark electrode Clean any carbon away from the electrode 7 Refit combustion chamber baffle 8 DIRECT VENT MODEL ONLY GC AND...

Reviews: