18
Ludlow Standard Model ECG
– Natural Gas
MAN and the Zzz symbols are flashing at the top of the display. Press and release the set button and
this will put the control into Manual snooze mode.
The default time period for the snooze time period is 1:00 hour. Pressing the set button again will show
y
ou the snooze time period remaining. This can be adjusted by pressing the “+” or “-“ buttons. The timer
period that can be set is from 1 minute to 4:00 hours.
After adjusting the time, press set again to enter the time setting required (or if left for a few seconds this
time is now stored and used).
Once this countdown timer has reached zero the fire will turn off.
10 - Thermostatic Mode
The handset has within it a thermostat sensor and this can be set so the fire will heat the room to
match he temperature set in the handset.
There are 2 temperature types that can be set:
• Day mode temperature that has a SUN symbol on the display
- the default temperature is 24 degrees Celsius.
• Night temperature that has a HALF MOON symbol on the display
- the default temperature setting is 18 degrees Celsius.
Hold handset and press and release the mode button several times as necessary until the display
has a thermometer symbol flashing at the top of the display. Press the set button to enter this mode.
Press the set button again to see the temperature setting that is set and the mode and on the left of
the display is a sun symbol showing it’s the day temperature.
If a different set temperature is required, while the display is showing this set temperature press
the “+” and “–” buttons to alter the setting. When finished either press set or leave and after a few
seconds the new setting will be accepted and the display will return to the time of day screen.
The fire will automatically turn to high or low rate depending on the set temperature. When the set
temperature is reached while the fire is in operation, the fire reduces the burner power level each
minute until the burner is off. The pilot will remain on for a further 30 minutes and if the set
temperature is still too high, the pilot will then also extinguish.
NOTE
: If at any time the power button is operated during Thermostat mode, the
control will cancel
any thermostat operation and return the control to manual mode.
Cleaning and Maintenance
This appliance should be inspected and serviced once a year by a qualified, competent and Gas Safe
registered person. The inspection and maintenance must at least ensure that the appliance is working
correctly and safely.
It is advisable to clean the appliance of any dust and debris before the heating season and especially if
the appliance has not been used for some time. This can be done with a soft brush and a vacuum cleaner
or a damp cloth and if required a non-abrasive cleaning agent. Do not use corrosive or abrasive
substances to clean the appliance.
Annual Service
For the AGA Warranty to be valid this stove must be services once a year by a Gas Safe Qualified
Engineer. After an annual service on this stove please complete the record sheet at the rear of the
manual