Fitting the 2 x Flue Collars to the Stove for a Top Exit Configuration (Vertical Flue)
You have already removed the Inner Glass and Seal to Access the Firebox
–
As described earlier in this manual
1. Lift off lid and store in a safe place.
2. The air inlet flue collar and gasket (150mm diameter) can now be accessed from the top of the fire
(M5 x 16mm cap screws x QTY 4)
3. Unscrew M5 flange screws (QTY x 6) remove front glass and frame and store in a safe place
4. Unscrew M5 flange nuts (QTY x 2) from the inside at the top of the fire and carefully remove the inner
heat shield (inner rear baffle plate) replace this inner heat shield once you have completed step 8
–
This must be replaced back into the firebox on completion
5. The exhaust flue collar & gasket (100mm diameter) can be accessed from the inside top of the fire
(M5 flange nuts QTY x 3)
6. The exhaust blanking plate & gasket can be accessed from the inside rear of the fire (M5 flange nuts
QTY x 3)
7. Unscrew M5 cap screws (QTY x 4) and remove back panel and store in a safe place
8. The air inlet blanking plate and gasket can be accessed from the rear of the fire (M5 cap screws QTY
x4)
9. Refit the parts as per the following steps in reverse for the above make sure the firebox is air tight on
all of the seals for the 2 x flue collars and front glass
10. Now fit the rear chain fixing kit
– as described earlier in this manual
11. Fit the 2 x locking screws into the flue pipe and flue collar as described earlier in this manual
Please note the stove is supplied with the air inlet and exhaust outlet blanking plates fitted to the
rear of the stove. So the 2 x flue collars (supplied loose) would be fitted to the top of the stove for
a vertical flue kit to be installed