Because the height of the cooker can be adjusted and
each connection is different it is difficult to give precise
dimensions. Ideally the house supply bayonet should be
in the shaded area shown in the diagram. This hose
should be fitted so that both inlet and outlet connections
are vertical so that the hose hangs downwards in a ‘U’
shape. A 3ft hose will need to be connected from the side.
For Natural Gas the flexible hose must be in accordance
with B.S. 689.
For LP Gas it should be capable of 50mbar pressure,
70ºC temperature rise and carry a red stripe, band or
label.
If in doubt contact, your supplier.
Screw connect the threaded end of the hose into the gas
inlet in the underside of the connector block on the back
of the cooker.
After completing the gas connection, check the cooker is
gas sound with a pressure test. When checking for gas
leaks do not use washing up liquid - this can corrode. Use
a product specifically manufactured for leak detection.
Pressure Testing
The gas pressure can be measured at the fish kettle
burner jet. Make sure that the cooker is not connected to
the electricity supply. Lift off the burner head. Fit the
pressure gauge to the jet. Turn on one of the other burners
and light it with a match. Turn on the control for the fish
kettle burner and press in the knob to allow the gas
through and register the pressure on the gauge.
For Natural gas cookers the pressure should be 20mbar.
For LP gas (propane) the pressure should be 37mbar.
Re-assemble burner top, making sure it is re-assembled
in the correct way on the burner body.
Electrical Connection
This appliance must be installed by a qualified electrician
to comply with the relevant regulations and also the local
electricity supply company requirements.
WARNING: THIS APPLIANCE MUST BE EARTHED.
NOTE:
The cooker must be connected to the correct
electrical supply as stated on the voltage label on the
cooker, through a suitable cooker control unit
incorporating a double pole switch having a contact
separation of at least 3mm in all poles. This cooker must
not be connected to an ordinary domestic power point.
The total electrical load of the appliance is approximately
8.8 kW. The cable size used should be suitable for this
load and comply with all local requirements.
Access to the mains terminal is gained by removing the
electrical terminal cover box on the back panel.
Connect the mains cable to the correct terminals for your
electrical supply type.
33