CONVERSION
Check the appliance is electrically safe and gas sound when you have finished.
24
Burner Cap
Burner Cap
Inner
Burner Base
Outer
Burner Head
Outer
Burner Head
Outer
Burner Base
Burner
Base Cup
Outer
Burner Base
A
B
C
Important!
•
Observe all governing codes and ordinances.
•
The range must be properly grounded.
•
Save these instructions for the local electrical inspector’s
use.
When servicing or replacing gas carrying components
disconnect from the gas supply before commencing
operation and check the appliance is gas sound after
completion. When checking for gas leaks use a liquid leak
detector at all joints and connections to check for leaks in
the system. Use a product specifically manufactured for leak
detection. Leak testing of the appliance shall be conducted in
accordance to the manufacturer’s instructions.
For Your Safety
DO NOT store or use combustible materials, gasoline or other
flammable vapors and liquids in the vicinity of this or any
other appliance.
Conversion to Propane
This appliance is supplied set for Natural gas. A conversion kit
for Propane gas is supplied with the range.
If the appliance is to be converted this must be done before
installation. The conversion must be performed by a qualified
LP gas installer. After conversion the installation must comply
with the relevant regulations and also the local electricity
supply company requirements. Read the instructions before
converting this appliance.
Failure to convert the appliance correctly could invalidate any
warranty or liability claims and lead to prosecution.
This instruction must be used in conjunction with the rest
of the appliance instruction, in particular for information on
Standards, range positioning, connection hose suitability, etc.
When servicing or replacing gas-carrying components
disconnect from gas before commencing operation and
check appliance is gas sound after completion.
DO NOT use reconditioned or unauthorized gas controls.
Orifices
Remove burner caps and heads
. Remove the
old orifices
; save the orifices removed from the
appliance for future use.
Fit the new orifices; see
for details. Reassemble in
the reverse order.
Table 8.1
8. Conversion to Another Gas
Fig. 8.1
Fig. 8.2
A
– Jet,
B
– Internal injector,
C
– External injector
Natural Gas
orifice
Propane Gas
orifice
Input
Jet
150
100
12,000 Btu/h
Jet
(front center burner)
188
122
18,000 Btu/h
Internal Injector
165
107
15,000 Btu/h
External Injector
42