INSTALLATION
Check the appliance is electrically safe and gas sound when you have finished.
30
ArtNo.281-0013 - Albertine SC - Electrical location
6” (15 cm) min
16” (41 cm)
Electrical Connection
When installed the range must be electrically grounded in
accordance with local codes or; in the absence of local codes
with the National Electrical Code ANSI/NFPA 70, latest edition.
In Canada the range must be installed in accordance with the
current CSA Standard C22.1 – Canadian Electrical Code Part 1.
Electrical Requirements
n
n
CAUTION!
For personal safety, do not use an extension cord
with this appliance. Remove the house fuse or open
the circuit breaker before beginning installation.
This appliance must be supplied with the proper voltage
and frequency, and connected to an individual, properly
grounded branch circuit, protected by a circuit breaker or
time-delay fuse, as noted on the rating plate.
Wiring must conform to National Electric Codes. If the electric
service provided does not meet the above specifications,
have a licensed electrician install an approved outlet.
Because range terminals are not accessible after range is in
position, flexible service conduit or cord must be used.
Provide Proper Electrical Supply
This range must be supplied with 240 V 60 Hz and connected
to an individual, properly grounded branch circuit protected
by a circuit breaker or time-delay fuse. If the electrical
service provided does not meet the above specifications, it is
recommended that a licensed electrician install an approved
outlet.
From January 1, 1996, the National Electric Code requires
that new construction (not existing) utilize a 4-conductor
connection to an electric range.
Connecting Using the Supplied Cord and Plug
Your range is shipped with a 4-prong plug to be used in a
NEMA 14-50R receptacle.
Recommended Electrical Outlet Locations
Locate the electric supply as illustrated
(Fig.7-15)
.
When connecting using a NEMA 14-50R receptacle, if possible
position it so that it can be accessed through the opening
at the rear of the drawer cavity. The range can then be easily
disconnected for servicing, etc.
Plug the range power cord into a properly grounded wall
receptacle.
Fig.7-15
ArtNo.281-0008 - 900SC - Electrical connection cover
Fig.7-16