CONVERSION
Check the appliance is electrically safe and gas sound when you have finished.
37
Important!
•
Observe all governing codes and ordinances.
•
The range must be properly grounded.
•
Save these instructions for the local electrical inspector’s
use.
When servicing or replacing gas carrying components
disconnect from the gas supply before commencing
operation and check the appliance is gas sound after
completion. When checking for gas leaks use a liquid leak
detector at all joints and connections to check for leaks in
the system. Use a product specifically manufactured for leak
detection. Leak testing of the appliance shall be conducted in
accordance to the manufacturer’s instructions.
For Your Safety
DO NOT store or use combustible materials, gasoline or other
flammable vapors and liquids in the vicinity of this or any
other appliance.
Conversion to Propane
This appliance is supplied set for Natural gas. A conversion kit
for Propane gas is supplied with the range.
If the appliance is to be converted this must be done before
installation. The conversion must be performed by a qualified
LP gas installer. After conversion the installation must comply
with the relevant regulations and also the local electricity
supply company requirements. Read the instructions before
converting this appliance.
Failure to convert the appliance correctly could invalidate any
warranty or liability claims and lead to prosecution.
This instruction must be used in conjunction with the rest
of the appliance instruction, in particular for information on
Standards, range positioning, connection hose suitability, etc.
When servicing or replacing gas-carrying components
disconnect from gas before commencing operation and
check appliance is gas sound after completion.
DO NOT use reconditioned or unauthorized gas controls.
Orifices
Remove burner caps and heads. Remove the old orifices; save
the orifices removed from the appliance for future use. Fit
the new orifices; see
Table 8-1
for details. Reassemble in the
reverse order.
Valve Adjustment
Disconnect from the electricity supply.
Pull off all the control knobs.
Open the oven door and remove the 3 fixing screws
underneath the control panel
(Fig.8-2)
.
Remove 3 screws from the upper rear of the control panel
Pull the bottom of the control panel forward and lift clear.
8. Conversion to Another Gas
Table 8-1
Fig.8-1
ArtNo.272-0025 - 90 Aga Professional - Control panel removal
Fig.8-2
Burner head
Burner base
Brass venturi
Natural Gas
Propane Gas
Center burner
205
118
Large Burners
150
99
Right front burner
112
68