background image

Shawbury Wood Stove

(Smoke Exempt)

INSTALLATION AND OPERATING INSTRUCTIONS

This appliance is hot while in operation and retains its heat for a long period of time after use.
Children, aged or infirm persons should be supervised at all times and should not be allowed
to touch the hot working surfaces while in use or until the appliance has thoroughly cooled.

When using the stove in situations where children, aged and/or infirm persons are 
present a fireguard must be used to prevent accidental contact with the stove.  The fireguard
should be manufactured in accordance with BS 8423:2002.

Summary of Contents for Shawbury

Page 1: ...irm persons should be supervised at all times and should not be allowed to touch the hot working surfaces while in use or until the appliance has thoroughly cooled When using the stove in situations w...

Page 2: ...rance to Combustibles 5 12 Safe Distance from Chimneys from Flammable materials 5 13 Stove Dimensions 6 14 Technical Data 6 15 Air Controls 7 16 Recommended Fuels 7 17 Refuelling 7 Refuelling onto a l...

Page 3: ...is installed by a Competent Person registered with a Government approved Competent Persons Scheme HETAS Ltd operate such a Scheme and a listing of their Registered Competent Persons can be found on t...

Page 4: ...ee elbows use 2 x 45o bends instead Horizontal runs of flue pipe should be avoided where it is unavoidable the maximum permitted horizontal run is 150mm The chimney flue must have the necessary cleara...

Page 5: ...d other appliances using air in operation at full rate i e extraction fans tumble dryers with all external doors and windows closed If spillage occurs following the above operation an additional air v...

Page 6: ...are must be taken to ensure that there is no risk of ignit ing combustible material an uninsulated flue pipe must be installed at least with a clearance of three times the diameter of the flue pipe i...

Page 7: ...th BS EN 13240 NOTE A suitable chimney minimum profile chimney draft tightness etc is a basic condition for the proper functioning of fireplace stoves See professional advice before installing the sto...

Page 8: ...open position for approximately 3 minutes allowing the new refuel charge to establish combustion before adjusting the air control to the desired setting Refuelling on to a low fire bed If there is in...

Page 9: ...room as the appliance If the alarm sounds unexpectedly follow the instructions given under Warning Note above The most common cause of fume emission is flue way or chimney blockage For your own safet...

Page 10: ...la tively small to permit the refractory to set prop erly and to season the stove 1 Before lighting the stove ensure that any build up in the firebox has been removed and that the ashpan has been empt...

Page 11: ...burning fuel If a build up of creosote occurs on the glass it may be due to draft conditions poor quality fuel or very slow burning for a long time Only clean glass when the stove is thoroughly coole...

Page 12: ...11 EXPLODED VIEW...

Page 13: ...A_0000_081 12 CSN_021103_M6X16 13 031_030_181 14 119A_0000_151 15 119A_0000_131 16 042A_0000_121 17 4901_000_008_23 18 CSN_022301_8X35 19 119A_2000_001 20 544_080_031 21 119A_0000_101 22 001A_0000_271...

Page 14: ...13...

Page 15: ...14...

Page 16: ...AGA Station Road Ketley Telford Shropshire TF1 5AQ UK Rev 001 DP261114 N00642AXX 15...