background image

9

8

GB F E D I N FIN 

Each end of each axis must be checked for calibration. If needed,

the axis can be calibrated, carefully following the instructions. You

can also take the laser to a service center for calibration.

Check and calibrate in this order:

Check both sides of X axis.

• If X is within spec, proceed to check both sides of Y.

• If X needs calibration, calibrate X

Check both sides of Y axis.

• If Y is within spec, proceed to final X to Y check

• If Y needs calibration, calibrate Y; proceed to X to Y check

Final X to Y check: compare X, X’, Y, Y’

4.1  Calibration overview

Calibration is electronic, using the laser keypad. The optional 
detector/remote control or optional small remote may also be used.

If the beam is visible, calibrate using the non-rotating point. If it’s
too bright to see the beam, you’ll use the detector and will need to
have the beam rotating. When you’re in calibration mode, press
the rotation key (7) on the laser to rotate the beam. 

The axis LED should blink slowly when in calibration mode. When
the laser is self-leveling or making an adjustment, the LED will blink
rapidly. 

IMPORTANT:
When pressing an arrow key to move the beam for cali-
bration, use short, rapid clicks. Do not hold the key
down. One click will move the beam a very small
amount (1/32" at 150' or 1mm at 100m). After pressing
the key, the LED will blink rapidly as the laser reacts.
Wait until the LED returns to a slow blink to proceed.

4.2   Horizontal checking and calibration

4.2.1 Checking X axis

1.

Place the laser on a flat surface or tripod 100 ft. (30 m) away from

a wall. Position so that X’ (noted on top of laser) is facing the wall.

Y

X

X’

Y’

1.

Insert the charger plug into the jack located at the back of 

the laser. 

2.

Plug the charger into an electrical outlet (110 volts or 220 volts).

3.

Charge it for 15 hours. 

3.3 Later recharges 

The GAT220 can be charged when working, if electricity is
available on the jobsite. Simply plug in the charger and keep
on working. You can also remove the battery, replace it with the
alkaline battery pack and charge the rechargeable batteries. 
For optimum life of the battery, it is recommended to charge the
battery after fully discharged. To assure battery life, do not
charge over 20 hours. The battery and the charger can be
damaged if damp. Always store and charge your instrument in
a dry and covered place.

4. Checking and adjusting your GAT220 

THIS CHAPTER IS VERY IMPORTANT.

Here are a few simple instructions to check your

GAT220 for calibration. The laser is a precision instru-

ment and it is important that you keep it calibrated

and in proper condition. The accuracy of your work is

completely your responsibility and you should check

your instrument before beginning each job, and espe-

cially after the instrument has taken a sharp jolt or

been dropped, or when temperature changes greater

than 50 degrees F (28 degrees C) have occurred.

The laser has 2 horizontal axes: X and Y, as indicated on the top of
the laser.

GAT220-08-2007  7/10/07  22:38  Page 8

Summary of Contents for AGATEC220

Page 1: ......

Page 2: ...Safety The GAT220 is a Class 3R laser manufactured to comply with the international rules of safety IEC 60825 1 2001 Although the power of the emission of the beam is less than 5mW in Class 3R the fo...

Page 3: ......

Page 4: ...lf level ing After it has leveled the head will start to rotate 3 To select the H I Alert press the H I key 3 The H I Alert func tion will be active 30 seconds after the GAT220 has finished its self l...

Page 5: ...pe 6 Press the MAN key to return to automatic mode CAUTION In manual mode the beam rotates even if the laser is not leveled The H I Alert function is not available when the unit is in manual mode When...

Page 6: ...calibrate using the non rotating point If it s too bright to see the beam you ll use the detector and will need to have the beam rotating When you re in calibration mode press the rotation key 7 on th...

Page 7: ...to change to the Y axis When the Y LED blinks slowly it s ready to be calibrated in Y axis If you re no longer in calibration mode 1 Turn off the laser 2 Hold the MAN 5 key While holding momentarily p...

Page 8: ...apacity The GAT220 laser is guaranteed to be free of manufacturing defects for a period of one year Any abnormal usage or if the instrument has been subjected to shock will void this warranty Under no...

Page 9: ...erence an up arrow move it up When a horizontal line appears on the display the detector is at the same level as the laser beam 5 Press the On Off key to turn the detector off It will automatically sh...

Page 10: ...n m ar a Niveau Electronique...

Page 11: ...plications de nivellement 1 2 Avertissement Le GAT220 est un produit laser de Classe 3R laser Il respecte la norme de s curit internationale IEC 60825 1 2001 Bien que la puissance d mission du laser n...

Page 12: ...tale 1 Le GAT220 peut tre utilis m me le sol ou sur un tr pied standard 5 8 11 2 Appuyer sur la touche On Off 1 L instrument se met a niveau automatiquement 3 Pour s lectionner le mode Tilt appuyer su...

Page 13: ...ique Le mode semi automatique signifie L axe Y est en mode manuel L axe X est en mode automatique Il vous est donc possible de faire une pente manuelle sur l axe Y en utilisant les touches 8 et 9 du c...

Page 14: ...llule de r ception si la visibilit le permet Ou arr ter la rotation et diriger le point laser manuellement vers le mur 4 Faire pivoter le laser de 180 Lorsque le laser s est recal marquer la position...

Page 15: ...u sur la touche 9 pour descendre le rayon au niveau du milieu des 2 marques 7 Enregistrer les donn es de l axe Y en appuyant sur la touche MAN 5 du clavier Si une erreur a pu se produire lors des op r...

Page 16: ...t de la r paration voire au maximum le remplacement de l appareil Tout d montage de l appareil effectu par des techniciens non habilit s annule la garantie Les sp cifications de cet instrument peuvent...

Page 17: ...PR CISION e a er n Caract ristiques techniques Distance maximale d utilisation 150 m Pr cision Fin 1 mm Standard 2 5 mm Autonomie Batterie 50 heures 9 V Alcaline Environnement Etanche IP 66 Dimensions...

Page 18: ...33 r b n m dis u us...

Page 19: ...x 501 982 0880 Email sales agl lasers com QBL Liegnitzer Str 1 3 D 42489 W lfrath Tel 49 0 2058 7881 0 Fax 49 0 2058 7881 52 Info quante baulaser de PRIM TOOLS 17 F Morecrown Commercial Building 108 E...

Reviews: