Select a suitable location for theSTE 40 to be installed. Please observe the following points:
-  Do not use locations where the unit could be subjected to  water or chemicals.
- Rubber feet of the Console:

Your console has been manufactured for general use. Some chemicals found in furniture
polish or other furniture care products may alter the substance of the rubber feet of the
unit. Due to this influence it may be possible that the rubber feet of the DSS Console may
leave some marks. We will not accept any liability for any of such occurrences. With
reference to new furniture or polished furniture we would suggest to use a non-slip
protective matt for your DSS Console.

Insert Button Label

Cleaning

Location

To clean your DSS Console 

use a soft damp cloth

. An antistatic cloth may also be used.

NEVER use a dry cloth

 as this could result in a static discharge which may damage electronic

components within the unit. Please take great care that 

NO MOISTURE

 will enter the console.

The label can be removed by inserting the finger
nail on the top of the plastic insert and housing.
Move the insert downwards until it is curved.
The label can now be removed.

To re-insert the label put the bottom of the clear
plastic strip in the bottom slot of the telephone
and follow the instruction above in reverse
order.

To give a professional appearance, labels can be
printed with the programming tool TK-Suite
directly from your PC.

Summary of Contents for STE 40

Page 1: ...User Manual STE 40 System Telephone Expansion DSS Console...

Page 2: ...43 AS 45 AS 200 IT from Version 7 1 Up to 48 STE 40 may be registered which will depend on the type of telephone system in use and firmware level Up to date firmware can be found in the download area...

Page 3: ...ctions 2 Safety Notice 2 About this User Manual 2 Table of Contents 3 Very Important Installation Note 3 Feature Description of the STE 40 4 Connection of STE 40 5 STE 40 Connections 6 Attach STE 40 t...

Page 4: ...or ST 40 System Phone The unit can be connected to any ST 31 or ST 40 and operated with telephone systems which are listed within the user instructions The STE 40 will compliment the system phone ST...

Page 5: ...ace Guide the cable along the cable channel underneath the ST 31 ST 40 telephone and the STE 40 expansion unit Connect the plug of the power supply STE 30 STE 40 ST 40 to the socket of the STE 40 mark...

Page 6: ...6 AGFEO System Telephone Expansion STE 40 100288010001 STE 40 AGFEO STE 40 Connections Connection for optional Power Supply Unit Connection to next STE 40 Connection to ST 40 or previous STE 40...

Page 7: ...7 AGFEO System Telephone Expansion STE 40 To attach the STE 40 to the System Phone press the hooks of the STE 40 into the slots provided of the ST 31 or ST 40 as shown below Attach STE 40 to ST 40...

Page 8: ...for each trunk line Night Service can be switched for all trunk lines Enable Disable Call Forward if designated extension does not answer an incoming call Special function buttons may be allocated Sw...

Page 9: ...neral function ie enter account code after function button is pressed To activate a Relays A special function Button may be assigned To reserve a line should all lines be engaged at the time Ring Back...

Page 10: ...Lock Release Diversion from Diversion to Wake Up Stored messages already listened to enabled Call Log entries already viewed on on set on Logged in active on on on Messages already read enabled on se...

Page 11: ...ion Extension Button DSS Line Button Timer Button Memory Dial Button LED on LED off LED flashes fast LED flahes slow TAM switched on TAM switched off Timer is on function is off Timer and function is...

Page 12: ...hone Expansion STE 40 Changing Button Assignment 31 z y Start Programming Press Button to be programmed on the STE40 Confirm entry Enter first letter of required function or browse using the arrow but...

Page 13: ...furniture we would suggest to use a non slip protective matt for your DSS Console Insert Button Label Cleaning Location To clean your DSS Console use a soft damp cloth An antistatic cloth may also be...

Page 14: ...is on hook and the telephone is idle Press the following buttons simultaneously 0 The ST 21 is now in service mode Press 1 for SoftwareUpdate Enter the telephone number of the Update Server which is 4...

Page 15: ...15 AGFEO System Telephone Expansion STE 40 Declaration of Conformity...

Page 16: ...ns that this belongs to the group of Electro and electronic apparatus In this context you are directed by the European regulation to dispose of used apparatus at the point of buying an item of equal p...

Reviews: