Data Roll Field
The column of numbers at the far left represents the location of the acquired
data in the state analyzer’s memory. The numbered positions are also known
as the state locations and are relative to the trigger state location, which is
always represented by 0.
The column of state locations along with its data can be rolled to display
offscreen data by using the data roll field. The data roll field is the small
rectangular box located in the middle of the state location column.
The data roll field is used to either roll the data listing or to select an exact
state for display. When the data roll field is light blue, the knob is active and
can roll data in either direction. If you touch the data roll field when it is light
blue, a pop-up keypad appears for the number of an exact state. When the
pop-up keypad is used, the data listing shifts, leaving the selected state in the
light blue data roll box.
Data Roll Field
Data roll field
State location
column
Pop-up keypad
The Compare Menu
Data Roll Field
7–14
Summary of Contents for 16517A
Page 3: ...The Agilent Technologies 16517A 4 GSa S Timing and 1 GSa S State Logic Analyzer ii ...
Page 5: ...iv ...
Page 11: ...Contents 6 ...
Page 12: ...1 General Information ...
Page 18: ...2 Probing ...
Page 29: ...2 12 ...
Page 30: ...3 The Format Menu ...
Page 42: ...4 The Trigger Menu ...
Page 79: ...4 38 ...
Page 80: ...5 The Listing Menu ...
Page 86: ...6 The Waveform Menu ...
Page 106: ...7 The Compare Menu ...
Page 122: ...8 The Chart Menu ...
Page 133: ...8 12 ...
Page 134: ...9 Markers and Stop Measurements ...
Page 149: ...9 16 ...
Page 150: ...10 Skew Adjust ...
Page 156: ...11 Error Messages ...
Page 165: ...11 10 ...
Page 166: ...12 Specifications and Characteristics ...
Page 176: ...13 Installation and Service ...
Page 189: ...13 14 ...
Page 193: ...Index 4 ...