Chapter 2 Operating Your Frequency Counter
Using the MATH Menu Keys
Operating Guide
2-29
2
Example Procedure for Filtering Data (Using Limits) During Stats
1
Using the procedure in the previous sub-section titled “Example Procedure for
Computing Stats,” set up the Counter to display the minimum frequency value
of an input signal.
2
Set the upper and lower limits. (Refer to the section in Chapter 1 titled “To Set
Limits of Measurements” if needed.)
3
Press Stats key until
USE:
is displayed.
4
Press one of the arrow keys to toggle to
IN LIMIT
state.
USE: IN LIMIT
is displayed.
5
Press Run key.
The Counter will now perform the statistical computations (that is, standard
deviation, mean, maximum, and minimum) on only those measurements that are
within the user-entered limits. The Counter then displays the statistics you picked
(minimum, in this case).
6
Press Stats key until
USE:
is displayed.
7
Press any one of the arrow keys to toggle to
ALL MEAS
state.
USE: ALL MEAS
is displayed.
8
Press Run key.
The Counter will now perform the statistical computations (that is, standard
deviation, mean, maximum, and minimum) on all measurements, whether they fall in
or out of the user-entered limits. The Counter then displays the statistic you picked
(minimum, in this case).
Summary of Contents for 53181A
Page 2: ...NOTES...
Page 14: ...Contents x Operating Guide...
Page 24: ...Preface xx Operating Guide...
Page 33: ...1 Getting Started...
Page 68: ...Chapter 1 Getting Started Making Measurements 1 36 Operating Guide 1...
Page 69: ...2 Operating Your Frequency Counter Operator s Reference...
Page 143: ...3 Specifications...
Page 160: ...Chapter 3 Specifications Introduction 3 18 Operating Guide...