General Information
14
Table 1-1a. Performance Specifications for Series 654xA and 655xA (Note 1)
Parameter
Agilent
Model Number and Parameter Value
Specifications are warranted over the temperature range 0 to 55
°
C with a resistive load and the output connected for local
sensing.
Output Ratings
Voltage:
6541A/6551A
6542A/6552A
6543A/6553A
6544A/6554A
6545A/6555A
0 - 8 V
0 - 20 V
0 - 35 V
0 - 60 V
0 - 120 V
Current:*
6541A
6542A
6543A
6544A
6545A
0 - 20 A
0 - 10 A
0 - 6 A
0 - 3.5 A
0 - 1.5 A
6551A 6552A 6553A 6554A 6555A
0 - 50 A
0 - 25 A
0 - 15 A
0 - 9 A
0 - 4 A
*Derate the output current 1% per
°
C from 40
°
C to 55
°
C.
Front Panel Programming Accuracy
(@ 25
°
±
5 °C)
6541A/6551A 6542A/6552A 6543A/6553A 6544A/6554A 6545A/6555A
Voltage
:
)
0.06% +5 mV
0.06% +10 mV
0.06% +15 mV
0.06% +26 mV
0.06% +51 mV
Current:
6541A 6542A 6543A 6544A 6545A
0.l4 % +26mA
0.l4 % +13mA
0.l4 % +7mA
0.l4 % +4mA
0.l4 % +2mA
6551A 6552A 6553A 6554A 6555A
0.l5 % +60mA
0.l5 % +25mA
0.l5 % +13mA
0.l5 % +8mA
0.l5 % +4mA
Ripple & Noise
(from 20 Hz to 20 MHz with outputs ungrounded, or with either output terminal grounded)
Constant Voltage (
rms):
6541A/6551A 6542A/6552A 6543A/6553A 6544A/6554A 6545A/6555A
300
μ
V
300
μ
V
400
μ
V
500
μ
V
700
μ
V
Constant Voltage
(p-p):
6541A/6551A 6542A/6552A 6543A/6553A 6544A/6554A 6545A/6555A
3 mV
3 mV
4 mV
5 mV
7 mV
Constant Current
(rms):
6541A 6542A 6543A 6544A 6545A
10 mA
5 mA
3 mA
1.5 mA
1 mA
6551A 6552A 6553A 6554A 6555A
25 mA
10 mA
5 mA
3 mA
2 mA
Readback Accuracy
(with respect to actual output @ 25
°
C
±
5 °C)
Voltage:
6541A/6551A 6542A/6552A 6543A/6553A 6544A/6554A 6545A/6555A
0.07% +6 mV
0.07% +15 mV
0.07% +25 mV
0.07% +40 mV
0.07% +80 mV
+Current
6541A 6542A 6543A 6544A 6545A
0.15% +26 mA
0.15% +13 mA
0.15% +6.7 mA
0.15% +4.1 mA
0.15% +1.7 mA
6551A 6552A 6553A 6554A 6555A
0.15% +67 mA
0.15% +26 mA
0.15% +15 mA
0.15% +7 mA
0.15% +3 mA
-Current
6541A 6542A 6543A 6544A 6545A
0.35% +40 mA
0.35% +20 mA
0.35% +12 mA
0.35% +6.8 mA
0.35% +2.9 mA
6551A 6552A 6553A 6554A 6555A
0.35% +100 mA
0.35% +44 mA
0.35% +24 mA
0.35% +15 mA
0.35% +7 mA
Load Regulation
(change in output voltage or current for any load change within ratings)
Voltage:
6541A/6551A 6542A/6552A 6543A/6553A 6544A/6554A 6545A/6555A
1 mV
2 mV
3 mV
4 mV
5 mV
Current:
6541A 6542A 6543A 6544A 6545A
1 mA
0.5 mA
0.25 mA
0.25 mA
0.25 mA
6551A 6552A 6553A 6554A 6555A
2 mA
1 mA
0.5 mA
0.5 mA
0.5 mA
Line Regulation
(change in output voltage or current for any line change within ratings)
Voltage:
6541A/6551A 6542A/6552A 6543A/6553A 6544A/6554A 6545A/6555A
0.5 mV
0.5 mV
1 mV
1 mV
2 mV
Current:
6541A 6542A 6543A 6544A 6545A
1 mA
0.5 mA
0.25 mA
0.25 mA
0.25 mA
6551A 6552A 6553A 6554A 6555A
2 mA
1 mA
0.75 mA
0.5 mA
0.5 mA