632
Chapter 7
Language Reference
TH Threshold
TH Threshold
Syntax
Figure 7-276
TH Syntax
Description
The TH command sets the minimum amplitude level and clips data at
this value. Default value is
−
90 dBm. See also MKPT. MKPT does not
clip data below its threshold.
NOTE
When a trace is in max-hold mode, if the threshold is raised above any
of the trace data, the data below the threshold will be permanently lost.