162
Multimeter Command Reference
IEEE 488.2 Common Command Quick Reference
The table below lists, by functional group, the IEEE 488.2 Common (*) Commands
that can be executed by the E1412A C-size 6½-Digit Multimeter. However,
commands are listed alphabetically in the following reference. Examples are shown
in the reference when the command has parameters or returns a non-trivial response;
otherwise, the command string is as shown in the table. For additional information,
refer to IEEE Standard 488.2-1987.
Category
Command
Title
Description
System Data
*IDN?
Identification
Returns the identification string of the B- or C-size
multimeter which includes the latest inguard and
outguard firmware versions.
AGILENT,E1412A,0,A.0x.0x-A.0x.0x
Internal
Operations
*RST
Reset
Resets the multimeter to:
FUNC:VOLT:DC,
VOLT:RANG 300V,
VOLT:RES 1 mV,
RANGE:AUTO ON,
NPLC 10,
ZERO:AUTO ON,
INP:IMP:AUTO OFF,
TRIG COUN 1,
TRIG:DELAY:AUTO ON,
TRIG:SOUR IMM,
SAMP:COUN 1.
OUTP:TTLT<
n
>:STAT OFF
Internal
Operations
*TST?
Self-Test
Returns “0” if self-test passes. Returns “1” if self-test
fails. Use SYST:ERR? to retrieve the error from the
multimeter. See “Self-Test Errors” beginning on
page
for a complete list of error numbers and
their description. Return multimeter to
Hewlett-Packard for repair if repair is required.
Synchronization
*OPC
*OPC?
*WAI
Operation Complete
Operation Complete Query
Wait to Complete
Operation Complete Command
Operation Complete Query
Wait-to-Continue Command
Status and Event *CLS
*ESE <
unmask
>
*ESE?
*ESR?
*SRE <
unmask
>
*SRE?
*STB?
Clear Status
Event Status Enable
Event Status Enable Query
Event Status Register Query
Service Request Enable
Service Request Enable Query
Read Status Byte Query
Clear Status Command
Standard Event Status Enable Command
Standard Event Status Enable Query
Standard Event Status Register Query
Service Request Enable Command
Service Request Enable Query
Read Status Byte Query
Bus Operation
*TRG
Bus Trigger
When the multimeter is in the wait-for-trigger state and
the trigger source is TRIGger:SOURce BUS, use
*TRG to trigger the multimeter.
Summary of Contents for Agilent E1412A
Page 2: ......
Page 10: ...8 Contents Notes...
Page 14: ...12 Notes...
Page 15: ...13 Notes...
Page 16: ...14 Notes...
Page 26: ...24 Agilent E1412A Multimeter Module Setup Chapter 1 Notes...
Page 194: ...192 Agilent E1412A Multimeter Error Messages Appendix B Notes...
Page 201: ...Index 199 Index Agilent E1412A User s Manual and SCPI Programming Guide...