Multimeter Command Reference
97
DATA
The multimeter can store up to 512 readings in internal memory. The
DATA
command allows you to determine how many readings are currently stored.
Subsystem Syntax
DATA
:POINts?
:POINts?
The
INITiate
command uses internal memory to store readings prior to a
FETCh?
command e.g., when a measurement is initiated by the
INITiate
command. You can
query the number of stored readings in memory by sending the
DATA:POINts?
command.
Comments
•
INITiate
command uses internal memory to store readings prior to using a
FETCh?
command. You use the
DATA:POINts?
command to query the
number of readings stored in internal memory to determine the amount of data
space to allocate on your computer to receive the data.