148
3
SNS Series
346 Series
N2002A
English URL
www.agilent.com/find/products
N2002A Noise Source Test Set
The N2002A Noise Source Test Set offers customers the opportunity
to calibrate their own noise sources with minimal levels of uncer-
tainty. With simple straightforward operations and low cost of
equipment it is now viable that this process can occur “in-house”
and thus drastically reduces downtime.
For engineers that currently run their own noise source cali-
bration service, the N2002A noise source test set is an ideal addition
to their test equipment. By incorporating this low-cost, self-
contained unit into a wider noise source calibration system, high
quality calibrations of noise sources can be made. When used within
a noise source calibration system the N2002A and Agilent N8975A
NFA series noise figure analyzer can also drastically reduce the
calibration time.
Key Literature
N2002A Noise Source Test Set 10 MHz to 26.5 GHz, Product Overview ,
p/n 5988-7228EN
Agilent Noise Source Calibration, Using the Agilent N8975A Noise Figure
Analyzer and the N2002A Noise Source Test Set, p/n 5988-7229EN
Ordering Information
N2002A
Noise Source Test Set
Accessories
N2002A-001
Accessory cable and adapters
Cable (x1): 11500E
3.5 mm female to female adapter (x 3): 1250-1749
3.5 mm female to type-N (female) adapter (x1): 1250-1745
Warranty
1-Year warranty as standard
1
Option not available in all countries.
• Simple calibration of noise sources with reduced uncertainty
• Traceable results to a national standard
• Availability for engineers who require on-site calibration
Noise Sources (cont.)
Noise Figure Analyzers
Ordering Information
346A
10 MHz to 18 GHz 346 Series Noise Source nominal ENR 5 dB
346B
10 MHz to 18 GHz 346 Series Noise Source nominal ENR 15 dB
346C
10 MHz to 26.5 GHz 346 Series Noise Source nominal ENR 15 dB
All of the 346 series noise sources are provided with an APC 3.5 (male)
connector as standard.
Connectors (excludes 346C)
346x-001
Type N (male) connector
346x-002
APC-7mm connector
346x-004
Type N (female) connector
Calibration Documentation
346x-A6J
ANSI Z540 compliant calibration with test data
Additional Documentation
346x-910
Extra operation manual
Custom Solution Options
346x-H10
Gold standards calibration (for use with the N2002A)
346B-H01
APC 3.5(m) connector with 21 dB nominal ENR
346B-H42
DBS Waveguide adapter and nominal ENR 5 dB
346CK01
1 GHz to 50 GHz 346 Series Noise Source nominal ENR 21 dB
Service Options:
Warranty and Service
Standard warranty is 1 year.
For warranty and service of 3 years, please order R-51B-001-3C: “1 year
Return-to-Agilent warranty extended to 3 years” (quantity = 1).
Calibration
1
For 3 years, order 36 months of the appropriate calibration plan shown
below. For 5 years, specify 60 months.
R-50C-001
Standard calibration plan
R-50C-002
Standard compliant calibration plan
R347B and Q347B Noise Sources
This series of broadband noise sources has been designed to cover
high frequency waveguide measurement applications.
Agilent 347 Partial Specifications
Instrument Model
Frequency Range
ENR Value
R347B
26.5 to 44 GHz
10 – 13 dB
Q347B
33 to 42 GHz
10 – 13 dB
42 to 50 GHz
6 – 12.5 dB
Instrument
Frequency Range
Max SWR
Reflection
Model
(GHz)
Coefficient
R347B
26 to 44
<1.42
0.17
Q347B
33 to 50
<1.57
0.22
Warranty
1-Year warranty as standard
Summary of Contents for All