120
Hardware Configuration Reference
handoffRx.interface
Syntax
handoffRx(1..16).interface:
string
The maximum length is 63 characters.
Description
Specifies the interface type connecting the handoff receiver to the E3238s system. Some
examples are hpib, vxi, and com1.
As many as 100 handoff receivers may be controlled by the E3238S system. The number 16
that appears in the syntax above is determined by the maxHandoffRxs parameter setting in
the
E3238s
resource file. An error occurs when you specify more than this setting.
Example
The following commands define the hardware configuration and driver program for a
handoff receiver:
handoffRx1.driver: C:/e3238s/lib/HD_8607.dll
handoffRx1.interface
:
rs232,COM1,9600
handoffRx1.label: VHF/UHF Rx
Note
When using a controller with a firewire interface, use “ASRL1” instead of “COM1” in the
interface parameter. (The firewire IO interface does not support an alias for the serial port
name.)
See Also