352
Chapter 10
Data Output
Saving and Recalling Instrument State
Saving and Recalling Instrument State
You can save the instrument state of the E5070B/E5071B into a file on mass storage (hard
disk drive or floppy disk drive) and then recall it later to reproduce that state. You can
select the stored data from the following four types.
Table 10-1
Stored data
Type
Stored data and usage
State only
(State Only)
Saves the setting
*1.For information on the saved target, refer to Appendix C, “List of Default Values.”
*1
of the E5070B/E5071B and reproduces the state when it was saved
by recalling it later into the E5070B/E5071B.
State and
calibration data
(State & Cal)
Saves the setting
of the E5070B/E5071B and calibration data (calibration coefficient
array
*2.For information on each array, refer to “Data Processing” on page 730.
*2
) to reproduce the state when it was saved by recalling it later into the
E5070B/E5071B. At this time, you can perform error correction of measured values
by using the recalled calibration data.
State and trace
(State & Trace)
of the E5070B/E5071B and traces (error-corrected data array
and error-corrected memory array
) to reproduce the state when it was saved by
recalling it later into the E5070B/E5071B. At this time, the traces are also recalled and
displayed on the screen.
State, calibration
data, and traces
(All)
of the E5070B/E5071B, calibration data, and traces to reproduce
the state when it was saved by recalling it later into the E5070B/E5071B. At this time,
the calibration data and traces are also recalled.
In addition, the “user-preset” function is provided to allow the user to freely set up an
instrument state recalled when the preset function is executed. For more information on
how to set it up, see “Setting the user preset function” on page 449 .
Compatibility of files related to saving and recalling
The compatibility of saving/recalling the instrument state file is as follows:
R
Compatibility between different models
•
Files saved with the E5070B cannot be recalled with the E5071B.
•
Files saved with the E5070A can be recalled with the E5070B, although the
opposite is not possible.
•
Files saved with the E5071A can be recalled with the E5071B, although the
opposite is not possible.
Recalling
E5070B
*1
E5071B
*2
E5070A
E5071A
Saved
file
E5070B
Y
N
N
N
E5071B
N
Y
N
N
E5070A
Y
N
Y
N
E5071A
N
Y
N
Y
Summary of Contents for E5070B
Page 6: ......
Page 30: ...24 Contents ...
Page 34: ...28 Chapter1 Precautions Before contacting us ...
Page 286: ...280 Chapter6 Data Analysis Using the Equation Editor ...
Page 430: ...424 Chapter12 Optimizing Measurements Performing a Segment by Segment Sweep segment sweep ...
Page 538: ...532 Chapter15 Measurement Examples Executing Power Calibration ...
Page 634: ...628 AppendixB Troubleshooting Warning Message ...
Page 732: ...726 AppendixD Softkey Functions Trigger Menu ...
Page 740: ...734 AppendixE General Principles of Operation Data Processing ...
Page 760: ...754 AppendixF Replacing the 8753ES with the E5070B E5071B Comparing Functions ...