650
Appendix D
Softkey Functions
Analysis Menu
(Continued)
Fixture Simulator
Topology
Port3 (bal)
4-3
Selects test ports 4 and 3 on the analyzer for connection with (balanced)
port 3 on the DUT (ports c and d in Table 7-8 on page 294) respectively.
:CALC{1-16}:FSIM:BAL:TOP:SSB
Cancel
Returns to the softkey display screen one level higher.
Property
Enables or disables the display of the balanced measurement topology
property. When enabled, calibration status information between test ports
will be displayed in a matrix format in the lower-right corner of the channel
window.
:CALC{1-16}:FSIM:BAL:TOP:PROP:S
TAT
Return
Returns to the softkey display screen one level higher.
BalUn
Enables or disables the balanced/unbalanced conversion function of active
trace. This function uses internal software to convert the results obtained
from an unbalanced test port on the E5070B/E5071B into characteristics of
a balanced port. The port converted into a balanced port will be
characterized by a common mode signal and a differential mode signal.
Measurement parameters are expressed as mixed mode S parameters. Use
the
Topology
to select the type of DUT port and the connection method to
test the ports.
:CALC{1-16}:FSIM:BAL:PAR{1-16}:ST
AT
Balun OFF
All Traces
Disables the balanced/unbalanced conversion function of all displayed
traces.
None
Balun ON
All Traces
Enables the balanced/unbalanced conversion function of all displayed
traces.
None
Measurement
Same as
. See “Measurement Menu” on page 701.
Port Matching
Displays softkeys for setting up the matching circuit function. Based on the measurement results, the matching
circuit function uses internal software to determine characteristics with a matching circuit inserted between the
DUT and the test ports.
Port Matching
Enables or disables the matching circuit function.
:CALC{1-16}:FSIM:SEND:PMC:STAT
Select Port
Displays softkeys for selecting the test port to which a matching circuit is added.
1
Selects test port 1 for adding a matching circuit.
:CALC{1-16}:FSIM:SEND:PMC:
PORT1
2
Selects test port 2 for adding a matching circuit.
:CALC{1-16}:FSIM:SEND:PMC:
PORT2
Selects test port 3 for adding a matching circuit.
:CALC{1-16}:FSIM:SEND:PMC:
PORT3
Selects test port 4 for adding a matching circuit.
:CALC{1-16}:FSIM:SEND:PMC:
PORT4
Cancel
Returns to the softkey display screen one level higher.
Select Circuit
Displays softkeys for selecting the type of matching circuit to be added.
None
Does not add any matching circuit to the port selected in the
Select Port
menu.
:CALC{1-16}:FSIM:SEND:PMC:
PORT{1-4} NONE
SeriesL -
ShuntC
Adds a series L - shunt C type matching circuit to the port selected in the
Select Port
menu.
:CALC{1-16}:FSIM:SEND:PMC:
PORT{1-4} SLPC
ShuntC -
SeriesL
Adds a shunt C - series L type matching circuit to the port selected in the
Select Port
menu.
:CALC{1-16}:FSIM:SEND:PMC:
PORT{1-4} PCSL
ShuntL -
SeriesC
Adds a shunt L - series C type matching circuit to the port selected in the
Select Port
menu.
:CALC{1-16}:FSIM:SEND:PMC:
PORT{1-4} PLSC
SeriesC -
ShuntL
Adds a series C - shunt L type matching circuit to the port selected in the
Select Port
menu.
:CALC{1-16}:FSIM:SEND:PMC:
PORT{1-4} SCPL
Key Operation
Function
SCPI Command
Summary of Contents for E5070B
Page 6: ......
Page 30: ...24 Contents ...
Page 34: ...28 Chapter1 Precautions Before contacting us ...
Page 286: ...280 Chapter6 Data Analysis Using the Equation Editor ...
Page 430: ...424 Chapter12 Optimizing Measurements Performing a Segment by Segment Sweep segment sweep ...
Page 538: ...532 Chapter15 Measurement Examples Executing Power Calibration ...
Page 634: ...628 AppendixB Troubleshooting Warning Message ...
Page 732: ...726 AppendixD Softkey Functions Trigger Menu ...
Page 740: ...734 AppendixE General Principles of Operation Data Processing ...
Page 760: ...754 AppendixF Replacing the 8753ES with the E5070B E5071B Comparing Functions ...