686
Appendix D
Softkey Functions
Calibration Menu
(Continued)
Mixer/Converter
Calibration
Scalar Cal (Manual)
Transmission
Displays the softkey to execute THRU standard measurements.
Thru x-y @
Freq x
[Thru]
Executes a THRU calibration on test ports x and y by using the
frequency that is set in test port x. The x and y change by the
selected test port and calibration method.
:SENS{1-16}:CORR:OFFS:COLL:THRU
Thru y-x @
Freq y
[Thru]
Executes a THRU calibration on test ports y and x by using the
frequency that is set in test port y. The x and y change by the
selected test port and calibration method.
:SENS{1-16}:CORR:OFFS:COLL:THRU
Return
Returns to the softkey display in one level higher.
Power Meter
Displays the softkey to execute a power calibration.
Use Sensor
Selects the channel of the power sensor you want to use for the
measurement of power calibration data.
:SENS{1-16}:CORR:OFFS:COLL:PMET
Port x @
Freq x
Executes a power calibration on test port x by using the frequency
that is set in test port x. The x changes by the selected test port and
calibration method.
:SENS{1-16}:CORR:OFFS:COLL:PMET
Port x @
Freq y
Executes a power calibration on test port x by using the frequency
that is set in test port y. The x and y change by the selected test port
and calibration method.
:SENS{1-16}:CORR:OFFS:COLL:PMET
Port y @
Freq x
Executes a power calibration on test port y by using the frequency
that is set in test port x. The x and y change by the selected test port
and calibration method.
:SENS{1-16}:CORR:OFFS:COLL:PMET
Port y @
Freq y
Executes a power calibration on test port y by using the frequency
that is set in test port y. The y changes by the selected test port and
calibration method.
:SENS{1-16}:CORR:OFFS:COLL:PMET
Return
Returns to the softkey display in one level higher.
Done
Terminates a calibration process and calculates the calibration
coefficients.
:SENS{1-16}:CORR:OFFS:COLL:SAVE
Cancel
Displays the softkey to cancel a calibration.
OK
Cancels a calibration process and clear the measurement data of
standard.
:SENS{1-16}:CORR:OFFS:COLL:CLE
Cancel
Returns to the softkey display in one level higher.
Return
Returns to the softkey display in one level higher.
Scalar Cal (ECal)
Displays the softkey to execute a scalar-mixer calibration by using the ECal.
Select Ports
Displays the softkey to select test ports and calibration methods you want to use for scalar-mixer calibration.
Port 1
Select 1-port calibration for the test port 1.
None
:
:
:
Port 4
Select 1-port calibration for the test port 4.
None
2-1 (fwd)
Select a scalar-mixer calibration for test port 1
→
2 (forward).
None
1-2 (rev)
Select a scalar-mixer calibration for test port 2
→
1 (reverse).
None
2,1 (both)
Select a scalar-mixer calibration for test port 1
→
2 and 2
→
1 (both
directions).
None
:
:
:
4-3 (fwd)
Select a scalar-mixer calibration for test port 3
→
4 (forward).
None
3-4 (rev)
Select a scalar-mixer calibration for test port 4
→
3 (reverse).
None
Key Operation
Function
SCPI Command
Summary of Contents for E5070B
Page 6: ......
Page 30: ...24 Contents ...
Page 34: ...28 Chapter1 Precautions Before contacting us ...
Page 286: ...280 Chapter6 Data Analysis Using the Equation Editor ...
Page 430: ...424 Chapter12 Optimizing Measurements Performing a Segment by Segment Sweep segment sweep ...
Page 538: ...532 Chapter15 Measurement Examples Executing Power Calibration ...
Page 634: ...628 AppendixB Troubleshooting Warning Message ...
Page 732: ...726 AppendixD Softkey Functions Trigger Menu ...
Page 740: ...734 AppendixE General Principles of Operation Data Processing ...
Page 760: ...754 AppendixF Replacing the 8753ES with the E5070B E5071B Comparing Functions ...