Safety 
Notices

This apparatus has been 
designed and tested in accor-
dance with IEC Publication 1010, 
Safety Requirements for Mea-
suring Apparatus, and has been 
supplied in a safe condition.  
This is a Safety Class I instru-
ment (provided with terminal for 
protective earthing).  Before 
applying power, verify that the 
correct safety precautions are 
taken (see the following warn-
ings).  In addition, note the 
external markings on the instru-
ment that are described under 
"Safety Symbols."

Warnings

• Before turning on the instru-
ment, you must connect the pro-
tective earth terminal of the 
instrument to the protective con-
ductor of the (mains) power 
cord. The mains plug shall only 
be inserted in a socket outlet 
provided with a protective earth 
contact. You must not negate 
the protective action by using an 
extension cord (power cable) 
without a protective conductor 
(grounding).  Grounding one 
conductor of a two-conductor 
outlet is not sufficient protec-
tion.

• Only fuses with the required 
rated current, voltage, and spec-
ified type (normal blow, time 
delay, etc.) should be used.  Do 
not use repaired fuses or short-
circuited fuseholders.  To do so 
could cause a shock or fire haz-
ard.

• If you energize this instrument 
by an auto transformer (for volt-
age reduction or mains isola-
tion), the common terminal must 
be connected to the earth termi-
nal of the power source.

• Whenever it is likely that the 

ground protection is impaired, 
you must make the instrument 
inoperative and secure it against 
any unintended operation.

• Service instructions are for 
trained service personnel. To 
avoid dangerous electric shock, 
do not perform any service 
unless qualified to do so.  Do not 
attempt internal service or 
adjustment unless another per-
son, capable of rendering first 
aid and resuscitation, is present.

• Do not install substitute parts 
or perform any unauthorized 
modification to the instrument.

• Capacitors inside the instru-
ment may retain a charge even if 
the instrument is disconnected 
from its source of supply.

• Do not operate the instrument 
in the presence of flammable 
gasses or fumes.  Operation of 
any electrical instrument in such 
an environment constitutes a 
definite safety hazard.

• Do not use the instrument in a 
manner not specified by the 
manufacturer.

To clean the instrument

If the instrument requires clean-
ing: (1) Remove power from the 
instrument. (2) Clean the exter-
nal surfaces of the instrument 
with a soft cloth dampened with 
a mixture of mild detergent and 
water. (3) Make sure that the 
instrument is completely dry 
before reconnecting it to a 
power source.

Safety Symbols

Instruction manual symbol:  the 
product is marked with this sym-
bol when it is necessary for you 
to refer to the instruction man-
ual in order to protect against 
damage to the product..

Hazardous voltage symbol.

Earth terminal symbol: Used to 
indicate a circuit common con-
nected to grounded chassis.

!

Summary of Contents for E5346A

Page 1: ...to a small area of a target system The Agilent Technologies E5346A probe has RCR isolation networks in the cable end that connects to the 38 pin AMP MICTOR Matched Impedance ConnecTOR connector The A...

Page 2: ...to select the part number of the correct shroud for your board thickness The kits listed consist of 5 MICTOR connectors and 5 support shrouds 4 Connect either the 38 pin probe or 38 pin adapter cable...

Page 3: ...7D 16710A 16711A 16712A 16715A 16716A 16717A 16718A 16719A 16750A 16751A or 16752A The following equivalent probe load diagram includes the logic analyzer and 38 pin MICTOR connector Equivalent probe...

Page 4: ...gilent publication number 5968 4632E Probing Solutions for Agilent Technologies Logic Analysis Systems for help on the terminations when using the Agilent Technologies E5351A 38 Pin Adapter Cable Use...

Page 5: ...5 Installation Note Agilent Technologies E5346A 38 Pin Probe and E5351A 38 Pin Adapter Cable 38 pin probe and adapter cable dimensions...

Page 6: ...ter Cable Notice the holes for mounting the support shrouds in the following illustration One of the holes is off center to allow 0 40 in 1 02 mm centers when using multiple connectors Board pad detai...

Page 7: ...7 Installation Note Agilent Technologies E5346A 38 Pin Probe and E5351A 38 Pin Adapter Cable Support shroud dimensions...

Page 8: ...not connect these pins They are SCL and SDA which are used by the logic analyzer with an emulator or analysis probe preprocessor to program or read target information Pins 6 8 10 38 These pins are od...

Page 9: ...5 3 D15 even 7 7 D14 even 9 9 D13 even 11 11 D12 even 13 13 D11 even 15 15 D10 even 17 17 D9 even 19 19 D8 even 21 21 D7 even 23 23 D6 even 25 25 D5 even 27 27 D4 even 29 29 D3 even 31 31 D2 even 33...

Page 10: ...and DC return for analysis probes 5 VDC 1 1 39 1 39 GROUND 3 2 40 2 40 Do not connect the following pins They are used by the logic analyzer with an emulator or analysis probe to program or read targ...

Page 11: ...terminal must be connected to the earth termi nal of the power source Whenever it is likely that the ground protection is impaired you must make the instrument inoperative and secure it against any u...

Page 12: ...ocument Warranty The material contained in this document is provided as is and is subject to being changed without notice in future editions Further to the maximum extent permitted by applica ble law...

Reviews: