Service Guide E8364-90026
2-5
PNA Series Microwave Network Analyzers
General Product Information
E8362B, E8363B, E8364B
Analyzer Options Available
Option 081, External Reference Switch
This upgrade adds a solid-state internal RF transfer switch in the R1 reference
receiver
path. The switch allows the instrument to easily switch between standard S-parameter
(non-frequency offset) measurements and frequency offset measurements such as relative
phase or absolute group delay that require an external reference mixer. The user can set
the switch manually or remotely, but it is best used with the frequency-converter
application (option 083), where it is controlled automatically during the vector-mixer
calibration procedure.
Option 083, Frequency Converter Measurement Application
This option adds an intuitive and easy-to-use user interface, advanced calibration choices
that provide exceptional amplitude and phase accuracy, and control of external signal
sources for use as local oscillators (both fixed and swept-LO measurements are supported).
A graphical set-up dialog box lets you quickly set up the instrument for single or dual
conversion devices. This set-up screen also helps you calculate and choose where mixing
and image products will fall.
Option 099, Firmware Upgrade
This upgrade provides the latest revision of firmware for the PNA series network
analyzers on CD-ROM. This firmware is user installable. The installation requires a USB
CD-ROM drive (see
) or an external computer connected to a
Local Area Network (LAN).
This firmware is also available on the Internet at the Agilent website:
http://www.agilent.com/find/pna
. (Select your analyzer’s model number in this website to
view available upgrades.)
Option 221, 2-Port Front Panel Upgrade
This option changes the front panel UI (user interface) to a touchscreen and softkey
interface with a new color LCD display. This option changes your analyzer from an “A”
model to a “C” model.
Option 897, Built-In Tests for Commercial Calibration
This option enables performance tests that are built into the analyzer that enable you to
perform ISO 9001 commercial calibration of your analyzer. Refer to
for a description of the commercial calibration.
Option 898 Built-In Tests for Standards Compliant Calibration
This option enables performance tests that are built into the analyzer that enable you to
perform ISO 17025 and ANSI Z540 standards compliant calibration of your analyzer. Refer
to
“Calibration Options” on page 2-12
for a description of the standards compliant
calibrations.
Summary of Contents for E8362B
Page 11: ...Service Guide E8364 90026 1 1 1 Safety and Regulatory Information ...
Page 19: ...Service Guide E8364 90026 2 1 2 General Product Information ...
Page 33: ...Service Guide E8364 90026 3 1 3 Tests and Adjustments ...
Page 83: ...Service Guide E8364 90026 4 1 4 Troubleshooting ...
Page 151: ...Service Guide E8364 90026 5 1 5 Theory of Operation ...
Page 185: ...Service Guide E8364 90026 6 1 6 Replaceable Parts ...
Page 269: ...Service Guide E8364 90026 7 1 7 Repair and Replacement Procedures ...
Page 351: ...Service Guide E8364 90026 8 1 8 General Purpose Maintenance Procedures ...