286
Agilent InfiniiVision 7000A Series Oscilloscopes Programmer's Guide
5
Commands by Subsystem
:HARDcopy:FFEed
Command Syntax
:HARDcopy:FFEed <ffeed>
<ffeed> ::= {{OFF | 0} | {ON | 1}}
The HARDcopy:FFEed command controls whether a formfeed is output
between the screen image and factors of a hardcopy dump.
ON (or 1) is only valid when PRINter0 or PRINter1 is set as the
:HARDcopy:FORMat type.
Query Syntax
:HARDcopy:FFEed?
The :HARDcopy:FFEed? query returns a flag indicating whether a formfeed
is output at the end of the hardcopy dump.
Return Format
<ffeed><NL>
<ffeed> ::= {0 | 1}
See Also
•
"Introduction to :HARDcopy Commands"
•
•
•
•
•