304
Agilent InfiniiVision 7000A Series Oscilloscopes Programmer's Guide
5
Commands by Subsystem
:MARKer:Y2Position
Command Syntax
:MARKer:Y2Position <position> [suffix]
<position> ::= Y2 cursor position in NR3 format
<suffix> ::= {mV | V | dB}
If the :MARKer:MODE is not currently set to WAVeform (see
on page 297), the :MARKer:Y1Position command:
•
Sets :MARKer:MODE to MANual.
•
Sets the Y2 cursor position to the specified value.
When the :MARKer:MODE is set to WAVeform, Y positions cannot be set.
Query Syntax
:MARKer:Y2Position?
The :MARKer:Y2Position? query returns current Y2 cursor position. This is
functionally equivalent to the obsolete :MEASure:VSTOp command/query.
Return Format
<position><NL>
<position> ::= Y2 cursor position in NR3 format
See Also
•
"Introduction to :MARKer Commands"
•
•
•
•
•
N O T E
If the front-panel cursors are off or are set to Binary or Hex Mode, the marker position
values are not defined and an error is generated. Make sure to set :MARKer:MODE to
MANual or WAVeform to put the cursors in the front-panel Normal mode.
Summary of Contents for InfiniiVision 7000A Series
Page 1: ...Agilent InfiniiVision 7000A Series Oscilloscopes Programmer s Guide...
Page 34: ...34 Agilent InfiniiVision 7000A Series Oscilloscopes Programmer s Guide 1 What s New...
Page 44: ...44 Agilent InfiniiVision 7000A Series Oscilloscopes Programmer s Guide 2 Setting Up...
Page 58: ...58 Agilent InfiniiVision 7000A Series Oscilloscopes Programmer s Guide 3 Getting Started...
Page 750: ...750 Agilent InfiniiVision 7000A Series Oscilloscopes Programmer s Guide 8 Error Messages...
Page 922: ...922 Agilent InfiniiVision 7000A Series Oscilloscopes Programmer s Guide Index...