Commands by Subsystem
5
Agilent InfiniiVision 7000A Series Oscilloscopes Programmer's Guide
437
:SBUS:SPI:BITorder
Command Syntax
:SBUS:SPI:BITorder <order>
<order> ::= {LSBFirst | MSBFirst}
The :SBUS:SPI:BITorder command selects the bit order, most significant bit
first (MSB) or least significant bit first (LSB), used when displaying data
in the serial decode waveform and in the Lister.
Query Syntax
:SBUS:SPI:BITorder?
The :SBUS:SPI:BITorder? query returns the current SPI decode bit order.
Return Format
<order><NL>
<order> ::= {LSBF | MSBF}
Errors
•
See Also
•
"Introduction to :SBUS Commands"
•
•
N O T E
This command is only valid on 4 (analog) channel oscilloscope models when the low-speed
IIC and SPI serial decode option (Option LSS) has been licensed.