:TRIGger:FLEXray:BAUDrate
Command Syntax
:TRIGger:FLEXray:BAUDrate <baudrate>
<baudrate> ::= {2500000 | 5000000 | 10000000}
The :TRIGger:FLEXray:BAUDrate command specifies the baud rate as
2.5 Mb/s, 5 Mb/s, or 10 Mb/s.
Query Syntax
:TRIGger:FLEXray:BAUDrate?
The :TRIGger:FLEXray:BAUDrate? query returns the current baud rate
setting.
Return Format
<baudrate><NL>
<baudrate> ::= {2500000 | 5000000 | 10000000}
See Also
•
"Introduction to :TRIGger Commands"
•
N O T E
This command is only valid on 4 (analog) channel oscilloscope models when the FlexRay
triggering and serial decode option (Option FLX) has been licensed.